Sequence Admittance Model Decoupling Method for Grid-Connected Converters

Impedance method is one of the classical methods for system stability analysis. In order to simplify the complexity of the model, it usually ignores the anti-diagonal elements of the sequence impedance matrix. However, the asymmetric control structure of the converters will lead to frequency coupling. When the frequency coupling is serious, ignoring the anti-diagonal elements will cause a large error. In this paper, the converter sequence admittance matrix considering phase-locked loop(PLL) and control system is established in d-q frame, and the reason of frequency coupling phenomenon is analyzed. Then, based on the characteristics and the constraints of the admittance matrix, the transfer function of the converter in the full band decoupling is solved, and the low and middle band decoupling method is designed. Finally, a simulation model in MATLAB verifies that the decoupling method of middle and low frequency band can effectively eliminate the frequency coupling, and the results of the sequence impedance method are consistent with the generalized Nyquist criterion after decoupling, which can accurately judge the stability of the system.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1109/icpea63589.2024.10784682
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sequence Admittance Model Decoupling Method for Grid-Connected Converters

Weiqiang Zhou, Jie Jun, Feng Gao, Ke Wang
Power Systems and Technologies
article

Sequence Admittance Model Decoupling Method for Grid-Connected Converters

Weiqiang Zhou, Jie Jun, Feng Gao, Ke Wang
article en

Abstract

Impedance method is one of the classical methods for system stability analysis. In order to simplify the complexity of the model, it usually ignores the anti-diagonal elements of the sequence impedance matrix. However, the asymmetric control structure of the converters will lead to frequency coupling. When the frequency coupling is serious, ignoring the anti-diagonal elements will cause a large error. In this paper, the converter sequence admittance matrix considering phase-locked loop(PLL) and control system is established in d-q frame, and the reason of frequency coupling phenomenon is analyzed. Then, based on the characteristics and the constraints of the admittance matrix, the transfer function of the converter in the full band decoupling is solved, and the low and middle band decoupling method is designed. Finally, a simulation model in MATLAB verifies that the decoupling method of middle and low frequency band can effectively eliminate the frequency coupling, and the results of the sequence impedance method are consistent with the generalized Nyquist criterion after decoupling, which can accurately judge the stability of the system.

Hunan Xiangdian Test Research Institute (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 78%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.