Research on Low Power Factor Standard Device Based on Sampling Method

With the proposal and implementation of the national "dual carbon" goals, the power system dominated by traditional power generation methods is gradually transforming into a new power system dominated by new energy, and low power factor is one of its typical characteristics. This paper mainly focuses on the application scenarios of low power factor in power systems, studies the power measurement standard device based on the sampling method, and proposes a wide-band voltage divider, a wide-band shunt and a dual-channel vector voltage analyzer device and a method for accurate phase measurement. A wide-band resistor divider and a squirrel cage shunt are used in this paper, and the phase error of the dual- channel vector voltage analyzer is experimentally analyzed. The overall system provides a high-precision measurement method for complex scenarios of power detection under low power factor.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1109/icpea63589.2024.10784793
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Low Power Factor Standard Device Based on Sampling Method

Ailing Geng, Wei Cen, Yang Ge, Wenbo Yao et al.
Advanced Sensor and Control Systems
article

Research on Low Power Factor Standard Device Based on Sampling Method

Ailing Geng, Wei Cen, Yang Ge, Wenbo Yao, Jing Meng, Xingzhi Liu
article en

Abstract

With the proposal and implementation of the national "dual carbon" goals, the power system dominated by traditional power generation methods is gradually transforming into a new power system dominated by new energy, and low power factor is one of its typical characteristics. This paper mainly focuses on the application scenarios of low power factor in power systems, studies the power measurement standard device based on the sampling method, and proposes a wide-band voltage divider, a wide-band shunt and a dual-channel vector voltage analyzer device and a method for accurate phase measurement. A wide-band resistor divider and a squirrel cage shunt are used in this paper, and the phase error of the dual- channel vector voltage analyzer is experimentally analyzed. The overall system provides a high-precision measurement method for complex scenarios of power detection under low power factor.

North China Electric Power University (CN), State Grid Corporation of China (China) (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 72%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Low Power Factor Standard Device Based on Sampling Method — Ailing Geng, Wei Cen, et al. · (2024) | TGRS Research Map | TGRS