Effect of IGBT Series and Parallel Combination on Current Transfer Characteristics of DC Vacuum Arc in Hybrid Breaking Process

With the development of DC grids, hybrid DC circuit breaker (HDCCB) has become the research hot-spot for DC interruption. For HDCCB composed of vacuum switches in parallel with IGBTs, the interruption capability is closely related to the current transfer characteristics in hybrid breaking process. The objective of this paper is to determine the effect of different series and parallel combinations of IGBTs on the current transfer characteristics in hybrid breaking process. When the number of parallel IGBTs increases from 3 to 9, the current transfer time decreases from 0.78 ms to 0.60 ms, and the transfer speed increases from 10.46 A/us to 13.5 A/us. As the number of series IGBT groups increases from 1 to 3, the current transfer time increases from 0.66 ms to 1.64 ms, and the transfer speed decreases from 9.45 A/us to 3.8 A/us. The IGBT series and parallel structures influence resistance and the on-state voltage drop of the IGBT branch. As the parallel number increase from 6 to 9, the on-state voltage drop decrease from 10.7 V to 9.8 V. And as the series number of IGBT groups increase from 1 to 3, the onstate voltage drop increase from 7.8V to 23.1V.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792477
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of IGBT Series and Parallel Combination on Current Transfer Characteristics of DC Vacuum Arc in Hybrid Breaking Process

Wendi Xu, Yingsan Geng, Zhiyuan Liu, Yu Chen et al.
Vacuum and Plasma Arcs
article

Effect of IGBT Series and Parallel Combination on Current Transfer Characteristics of DC Vacuum Arc in Hybrid Breaking Process

Wendi Xu, Yingsan Geng, Zhiyuan Liu, Yu Chen, Hui Ma, Chen Fu, Yuanbing Zhang
article en

Abstract

With the development of DC grids, hybrid DC circuit breaker (HDCCB) has become the research hot-spot for DC interruption. For HDCCB composed of vacuum switches in parallel with IGBTs, the interruption capability is closely related to the current transfer characteristics in hybrid breaking process. The objective of this paper is to determine the effect of different series and parallel combinations of IGBTs on the current transfer characteristics in hybrid breaking process. When the number of parallel IGBTs increases from 3 to 9, the current transfer time decreases from 0.78 ms to 0.60 ms, and the transfer speed increases from 10.46 A/us to 13.5 A/us. As the number of series IGBT groups increases from 1 to 3, the current transfer time increases from 0.66 ms to 1.64 ms, and the transfer speed decreases from 9.45 A/us to 3.8 A/us. The IGBT series and parallel structures influence resistance and the on-state voltage drop of the IGBT branch. As the parallel number increase from 6 to 9, the on-state voltage drop decrease from 10.7 V to 9.8 V. And as the series number of IGBT groups increase from 1 to 3, the onstate voltage drop increase from 7.8V to 23.1V.

State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 78%
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.