Experimental Study on the Interruption Characteristics Applied by Underwater Arc

Arc discharge in water can generate exceptionally high voltages, which has great potential to be used in DC fault protection applications. When the arc voltage exceeds the DC system voltage, the rising current is halted and begins to decrease until it is turned off. The increase in water pressure, arc elongation, and enhanced convective heat transfer all contribute to a rapid increase in underwater arc voltage. This paper presents a device specially designed for underwater arc discharge. Water is fully sealed in the device as arc extinguishing medium. The internal deflection contacts operated with repulsion mechanism are proposed to realize circuit open and close. An external transverse magnetic field is used to regulate the underwater arc. Furthermore, the interruption characteristics influenced by motion speed and magnetic field strength are discussed. The experimental results demonstrate that underwater arc voltage can easily exceed 5 kV, and currents of up to 17 kA can be successfully interrupted.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10791520
Primary Topic
Risk and Safety Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on the Interruption Characteristics Applied by Underwater Arc

Rong Mingzhe, Yi Wu, Ke Qichen, He Hailong et al.
Risk and Safety Analysis
article

Experimental Study on the Interruption Characteristics Applied by Underwater Arc

Rong Mingzhe, Yi Wu, Ke Qichen, He Hailong, Bai Chenfei
article en

Abstract

Arc discharge in water can generate exceptionally high voltages, which has great potential to be used in DC fault protection applications. When the arc voltage exceeds the DC system voltage, the rising current is halted and begins to decrease until it is turned off. The increase in water pressure, arc elongation, and enhanced convective heat transfer all contribute to a rapid increase in underwater arc voltage. This paper presents a device specially designed for underwater arc discharge. Water is fully sealed in the device as arc extinguishing medium. The internal deflection contacts operated with repulsion mechanism are proposed to realize circuit open and close. An external transverse magnetic field is used to regulate the underwater arc. Furthermore, the interruption characteristics influenced by motion speed and magnetic field strength are discussed. The experimental results demonstrate that underwater arc voltage can easily exceed 5 kV, and currents of up to 17 kA can be successfully interrupted.

State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
National Natural Science Foundation of China
Life below water
Openalex Percentile: Top 76%
Risk and Safety Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Study on the Interruption Characteristics Applied by Underwater Arc — Rong Mingzhe, Yi Wu, et al. · (2024) | TGRS Research Map | TGRS