Design of Priority Driving Scheme for Nuclear Power Plant Protection System Based on DCS Architecture

CIM (Component Interface Module) is an important part of nuclear power plant protection system. Its main function is to drive the safety level actuator action after prioritizing automatic or manual commands from different safety levels, so as to complete specific safety functions. Through in-depth research on the overall architecture of DCS (Digital Control System) of ACPR1000 nuclear power unit and the transmission path of safety-level actuator drive instructions in DCS architecture, the defects of safety-level actuator controlled by NC-VDU(Non-Classified Visual Display Unit) call screen mode in existing design are summarized, and the design idea of using NC-VDU to directly control safety-level actuator is proposed. Based on the design idea, the priority driver scheme of CIM is designed. This design simplifies the operator monitoring means and the equipment size of the MCR (Main Control Room), while significantly reducing the cost, and provides a reference for the design of the compact layout of the MCR.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1109/icpea63589.2024.10784718
Primary Topic
Safety and Risk Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Priority Driving Scheme for Nuclear Power Plant Protection System Based on DCS Architecture

Yuandong Guo, Yangyang Du, Chao Shen, Guojun Pan et al.
Safety and Risk Management
article

Design of Priority Driving Scheme for Nuclear Power Plant Protection System Based on DCS Architecture

Yuandong Guo, Yangyang Du, Chao Shen, Guojun Pan, Jiang Wu, Wei Guo, Shiyun Quan, Yan Wang
article en

Abstract

CIM (Component Interface Module) is an important part of nuclear power plant protection system. Its main function is to drive the safety level actuator action after prioritizing automatic or manual commands from different safety levels, so as to complete specific safety functions. Through in-depth research on the overall architecture of DCS (Digital Control System) of ACPR1000 nuclear power unit and the transmission path of safety-level actuator drive instructions in DCS architecture, the defects of safety-level actuator controlled by NC-VDU(Non-Classified Visual Display Unit) call screen mode in existing design are summarized, and the design idea of using NC-VDU to directly control safety-level actuator is proposed. Based on the design idea, the priority driver scheme of CIM is designed. This design simplifies the operator monitoring means and the equipment size of the MCR (Main Control Room), while significantly reducing the cost, and provides a reference for the design of the compact layout of the MCR.

China General Nuclear Power Corporation (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 67%
Safety and Risk Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.