Dynamic Voltage Restorer Appied for Urban Rail Power Supply System

To solve the voltage sag problem in metro escalators, Dynamic Voltage Restorer (DVR) for urban rail power supply system is proposed in this paper. Firstly, the Dynamic Voltage Restorer designed in this paper draws energy from the DC traction network without additional energy storage elements, which solves the energy storage problem of the conventional Dynamic Voltage Restorer. Secondly, a single-phase full-bridge inverter circuit is used to achieve phase-independent voltage compensation so that various voltage sag can be handled. Thirdly, an improved proportional-resonant(PR) composite control strategy is selected to realize the voltage tracking of the DVR. Finally, A Hardware-in-the-loop simulation platform is used to conduct simulation experiments in this paper, and the simulation results show that the model proposed in this paper can accurately realize the effective compensation of voltage sag on the metro escalator and ensure the normal operation of the escalator.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1109/icpea63589.2024.10784670
Primary Topic
Railway Systems and Energy Efficiency
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Voltage Restorer Appied for Urban Rail Power Supply System

Ruichang Qiu, Yonghui Li, Ming Gao, Gang Zhang
Railway Systems and Energy Efficiency
article

Dynamic Voltage Restorer Appied for Urban Rail Power Supply System

Ruichang Qiu, Yonghui Li, Ming Gao, Gang Zhang
article en

Abstract

To solve the voltage sag problem in metro escalators, Dynamic Voltage Restorer (DVR) for urban rail power supply system is proposed in this paper. Firstly, the Dynamic Voltage Restorer designed in this paper draws energy from the DC traction network without additional energy storage elements, which solves the energy storage problem of the conventional Dynamic Voltage Restorer. Secondly, a single-phase full-bridge inverter circuit is used to achieve phase-independent voltage compensation so that various voltage sag can be handled. Thirdly, an improved proportional-resonant(PR) composite control strategy is selected to realize the voltage tracking of the DVR. Finally, A Hardware-in-the-loop simulation platform is used to conduct simulation experiments in this paper, and the simulation results show that the model proposed in this paper can accurately realize the effective compensation of voltage sag on the metro escalator and ensure the normal operation of the escalator.

Beijing Jiaotong University (CN)
Beijing Municipal Natural Science Foundation
Sustainable cities and communities
Openalex Percentile: Top 65%
Railway Systems and Energy Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines