Evaluation and Optimization of Circuit Breaker Opening Performance Based on Arc Simulation

Circuit breakers play a crucial role in ensuring the safety and reliability of power systems by interrupting circuits during electrical faults. However, the matching between the operating mechanism design and the arc chamber airflow field has been seldom addressed in previous studies, which has somewhat constrained the enhancement and optimization of circuit breaker performance. Addressing this issue, this study employs arc simulation technology to qualitatively evaluate and propose optimization directions for circuit breaker opening performance. This paper delineates the pivotal role of arc simulation technology in circuit breaker design and evaluation and scrutinizes the prevailing challenges and constraints in current circuit breaker designs, particularly the mismatch between operating mechanism design and arc chamber airflow field. Subsequently, the establishment of the arc model is elaborated upon, encompassing the theoretical foundation, parameter settings, and applicable scope, laying the groundwork for subsequent simulation studies. Through arc simulation of the 80kA L90 break condition, this study monitors arc voltage, identifies critical arc extinction moments, and obtains critical arc temperatures at that moment, thereby delineating critical extinction regions. Subsequently, an analysis is conducted to ascertain whether peak pressure and velocity values in the arc chamber airflow field match the critical arc extinction moment, evaluating the effectiveness of arc extinction and highlighting the significance of matching the operating mechanism's motion characteristics with the airflow field structure design. The findings of this study underscore that the degree of matching between the operating mechanism design and arc chamber airflow field significantly influences circuit breaker performance. The utilization of arc simulation offers novel insights and avenues for optimizing circuit breaker design. Consequently, the research outcomes of this study hold profound theoretical and practical implications for enhancing circuit breaker performance and improving power grid safety.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792473
Primary Topic
Evaluation and Optimization Models
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation and Optimization of Circuit Breaker Opening Performance Based on Arc Simulation

Zhongyang Luo, Hao Sun, Ziqi Liu, Yi Wu et al.
Evaluation and Optimization Models
article

Evaluation and Optimization of Circuit Breaker Opening Performance Based on Arc Simulation

Zhongyang Luo, Hao Sun, Ziqi Liu, Yi Wu, Xinyu Zhang
article en

Abstract

Circuit breakers play a crucial role in ensuring the safety and reliability of power systems by interrupting circuits during electrical faults. However, the matching between the operating mechanism design and the arc chamber airflow field has been seldom addressed in previous studies, which has somewhat constrained the enhancement and optimization of circuit breaker performance. Addressing this issue, this study employs arc simulation technology to qualitatively evaluate and propose optimization directions for circuit breaker opening performance. This paper delineates the pivotal role of arc simulation technology in circuit breaker design and evaluation and scrutinizes the prevailing challenges and constraints in current circuit breaker designs, particularly the mismatch between operating mechanism design and arc chamber airflow field. Subsequently, the establishment of the arc model is elaborated upon, encompassing the theoretical foundation, parameter settings, and applicable scope, laying the groundwork for subsequent simulation studies. Through arc simulation of the 80kA L90 break condition, this study monitors arc voltage, identifies critical arc extinction moments, and obtains critical arc temperatures at that moment, thereby delineating critical extinction regions. Subsequently, an analysis is conducted to ascertain whether peak pressure and velocity values in the arc chamber airflow field match the critical arc extinction moment, evaluating the effectiveness of arc extinction and highlighting the significance of matching the operating mechanism's motion characteristics with the airflow field structure design. The findings of this study underscore that the degree of matching between the operating mechanism design and arc chamber airflow field significantly influences circuit breaker performance. The utilization of arc simulation offers novel insights and avenues for optimizing circuit breaker design. Consequently, the research outcomes of this study hold profound theoretical and practical implications for enhancing circuit breaker performance and improving power grid safety.

Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 71%
Evaluation and Optimization Models
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.