Investigation on Switching Overvoltage of ±550kV DC GIS in Offshore Wind Farm

DC gas-insulated switchgear (DC GIS) in offshore wind farms significantly reduces the occupied space compared to air-insulated switchgear, lowering the cost of offshore platforms. In offshore HVDC systems, the DC GIS withstands considerable overvoltage during faults. Research of overvoltage stress in DC GIS is vital to the system. The study addresses the critical aspect of the arrester configuration scheme and overvoltage stress of ±550kV DC GIS. Offshore wind farm flexible DC grid connection with ±550kV symmetric bipolar system topology is established in the PSCAD/EMTDC platform. Then, the paper investigates the overvoltage withstood by the DC GIS surge arrester under different fault conditions and locations. The study organizes and defines stress calculation criteria for GIS. Finally, the voltage stress level of ±550kV DC GIS is calculated and analyzed. The results show that ±550kV DC GIS switching impulse withstand voltage is over 1068 kV in offshore wind farms.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792454
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on Switching Overvoltage of ±550kV DC GIS in Offshore Wind Farm

Yingsan Geng, Yifan Chen, Siyuan Liu, Zhiyuan Liu et al.
High-Voltage Power Transmission Systems
article

Investigation on Switching Overvoltage of ±550kV DC GIS in Offshore Wind Farm

Yingsan Geng, Yifan Chen, Siyuan Liu, Zhiyuan Liu, Liudan Wang, Ziao Yuan
article en

Abstract

DC gas-insulated switchgear (DC GIS) in offshore wind farms significantly reduces the occupied space compared to air-insulated switchgear, lowering the cost of offshore platforms. In offshore HVDC systems, the DC GIS withstands considerable overvoltage during faults. Research of overvoltage stress in DC GIS is vital to the system. The study addresses the critical aspect of the arrester configuration scheme and overvoltage stress of ±550kV DC GIS. Offshore wind farm flexible DC grid connection with ±550kV symmetric bipolar system topology is established in the PSCAD/EMTDC platform. Then, the paper investigates the overvoltage withstood by the DC GIS surge arrester under different fault conditions and locations. The study organizes and defines stress calculation criteria for GIS. Finally, the voltage stress level of ±550kV DC GIS is calculated and analyzed. The results show that ±550kV DC GIS switching impulse withstand voltage is over 1068 kV in offshore wind farms.

State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 78%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.