Multi-Physics Field Coupling Simulation of $\text{SF}_{6}$ Gasfilled GIS Disconnecting Switch Contact Temperature

Thermal failure is one of the main causes of GIS failure, the internal contact temperature is a direct temperature rise indicator for the thermal failure of GIS disconnecting switches, and multi-physics field coupled simulation is one of the important means to study the internal temperature rise of GIS disconnecting switches to heat up, so it is of great significance to study the contact temperature of GIS disconnecting switches through multi-physics field simulation. In this paper, firstly, the mathematical models of electromagnetic field and temperaturefluid field are constructed, and then, taking the 110 kV GIS disconnecting switch as the research object, the physical modeling is carried out after the simplification of the actual model, and the electric-thermal-fluid three-field coupling simulation model is established by using the two circles to equate the contact resistance of the GIS disconnecting switch. Based on the consideration of skin effect and neighborhood effect and electromagnetic simulation, the loss distribution of GIS disconnecting switch is calculated. The calculated loss is coupled to the temperature fluid field as a heat source to obtain the temperature field distribution of the GIS disconnecting switch contacts. The results show that: the highest point temperature at the conductor is <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$69.06{ }^{\circ} \mathrm{C}$</tex>, located in the top of the uppermost conductor contacts, the internal air is heated upward to form the phenomenon of three-phase conductor temperature increases sequentially, but the trend of increase is small.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792510
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Physics Field Coupling Simulation of $\text{SF}_{6}$ Gasfilled GIS Disconnecting Switch Contact Temperature

Yihong Lin, Dengfeng Wei, Ye Chen, Zhiwen Zhang
Thermal Analysis in Power Transmission
article

Multi-Physics Field Coupling Simulation of $\text{SF}_{6}$ Gasfilled GIS Disconnecting Switch Contact Temperature

Yihong Lin, Dengfeng Wei, Ye Chen, Zhiwen Zhang
article en

Abstract

Thermal failure is one of the main causes of GIS failure, the internal contact temperature is a direct temperature rise indicator for the thermal failure of GIS disconnecting switches, and multi-physics field coupled simulation is one of the important means to study the internal temperature rise of GIS disconnecting switches to heat up, so it is of great significance to study the contact temperature of GIS disconnecting switches through multi-physics field simulation. In this paper, firstly, the mathematical models of electromagnetic field and temperaturefluid field are constructed, and then, taking the 110 kV GIS disconnecting switch as the research object, the physical modeling is carried out after the simplification of the actual model, and the electric-thermal-fluid three-field coupling simulation model is established by using the two circles to equate the contact resistance of the GIS disconnecting switch. Based on the consideration of skin effect and neighborhood effect and electromagnetic simulation, the loss distribution of GIS disconnecting switch is calculated. The calculated loss is coupled to the temperature fluid field as a heat source to obtain the temperature field distribution of the GIS disconnecting switch contacts. The results show that: the highest point temperature at the conductor is <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$69.06{ }^{\circ} \mathrm{C}$</tex>, located in the top of the uppermost conductor contacts, the internal air is heated upward to form the phenomenon of three-phase conductor temperature increases sequentially, but the trend of increase is small.

Fujian Electric Power Survey & Design Institute (CN)
Climate action
Openalex Percentile: Top 72%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.