Attaining reactive power capability requirements for offshore wind power systems

The prospected diffusion of offshore wind farms (OWFs), to be connected to high-voltage transmission networks, arises the need of dealing with specific technical requirements posed in grid codes by transmission system operators (TSOs). Among them, the compliance with specific reactive power capabilities at point of common coupling can have significant implications in the design stage, for the definition of the needed size and position of compensation devices. In this context, an optimisation problem is proposed in this paper to determine the size of a reactive power compensation device coping with grid code requirements to connect an OWF to transmission system. The problem involves full AC load flow constraints along with nodal voltage and power rating boundaries. The proposed procedure is applied to an offshore wind farm test system to attain the Italian TSO grid code rules.

Authors

Institutions

Publication Details

Published
2024-10-21
DOI
https://doi.org/10.1109/synergymed62435.2024.10799310
Citations
1
Primary Topic
Power System Reliability and Maintenance
Type
article
Field-Weighted Citation Impact
0.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Attaining reactive power capability requirements for offshore wind power systems

Giuseppe Forte, Maria Dicorato, Francesca Marasciuolo, Gioacchino Tricarico
1 citations
Power System Reliability and Maintenance
0.36
article

Attaining reactive power capability requirements for offshore wind power systems

Giuseppe Forte, Maria Dicorato, Francesca Marasciuolo, Gioacchino Tricarico
article en
1 citations

Abstract

The prospected diffusion of offshore wind farms (OWFs), to be connected to high-voltage transmission networks, arises the need of dealing with specific technical requirements posed in grid codes by transmission system operators (TSOs). Among them, the compliance with specific reactive power capabilities at point of common coupling can have significant implications in the design stage, for the definition of the needed size and position of compensation devices. In this context, an optimisation problem is proposed in this paper to determine the size of a reactive power compensation device coping with grid code requirements to connect an OWF to transmission system. The problem involves full AC load flow constraints along with nodal voltage and power rating boundaries. The proposed procedure is applied to an offshore wind farm test system to attain the Italian TSO grid code rules.

Polytechnic University of Bari (IT)
Affordable and clean energy
Openalex Percentile: Top 36%
Power System Reliability and Maintenance
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Attaining reactive power capability requirements for offshore wind power systems — Giuseppe Forte, Maria Dicorato, et al. · (2024) | TGRS Research Map | TGRS