Surface Roughness of Conductor Affecting Surface Charge Distribution of Real-Sized DC GIS/GIL Insulator

Direct current gas-insulated switchgear (GIS/GIL) stands as a pivotal apparatus within high-voltage direct current (HVDC) transmission systems, exerting a paramount influence on achieving long-distance, high-reliability, high-capacity power transmission, and fostering the development of clean energy sources. However, during prolonged energized operation in DC systems, the issue of surface charge accumulation on insulators emerges as a critical factor leading to insulation breakdown. In this paper, based on a ±550 KV DC GIS prototype, a real-sized platform for measuring surface charges on bushing insulators was established. This study explores the influence of different surface roughness of the central electrode on the surface charge distribution of bushing insulators under varying gas environments. The results indicate that electrode roughness primarily affects the generation of localized charges.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792451
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface Roughness of Conductor Affecting Surface Charge Distribution of Real-Sized DC GIS/GIL Insulator

Ximing Gao, Yuan La, Yingying Le, Wei Luo et al.
High voltage insulation and dielectric phenomena
article

Surface Roughness of Conductor Affecting Surface Charge Distribution of Real-Sized DC GIS/GIL Insulator

Ximing Gao, Yuan La, Yingying Le, Wei Luo, Xinghua Zhang, Chao Gao
article en

Abstract

Direct current gas-insulated switchgear (GIS/GIL) stands as a pivotal apparatus within high-voltage direct current (HVDC) transmission systems, exerting a paramount influence on achieving long-distance, high-reliability, high-capacity power transmission, and fostering the development of clean energy sources. However, during prolonged energized operation in DC systems, the issue of surface charge accumulation on insulators emerges as a critical factor leading to insulation breakdown. In this paper, based on a ±550 KV DC GIS prototype, a real-sized platform for measuring surface charges on bushing insulators was established. This study explores the influence of different surface roughness of the central electrode on the surface charge distribution of bushing insulators under varying gas environments. The results indicate that electrode roughness primarily affects the generation of localized charges.

China Southern Power Grid (China) (CN)
Openalex Percentile: Top 85%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.