Grid-Forming PV System for Frequency Ancillary Services Provision

With the increasing penetration of photovoltaic (PV) systems posing challenges to power system stability, this paper investigates the effectiveness of grid-forming controlled PV systems in providing frequency ancillary services. The study implements the Virtual Synchronous Machine strategy, utilizing DC-link capacitor energy for inertial response provision (DCVQVSM), integrated within a grid-forming topology. To ensure power-frequency droop control, an additional control loop is introduced within the DCVQ-VSM topology. The efficacy of this control system is proved through simulations conducted on a simple two-bus system and a fully-electrified active distribution network (ADN). Both case studies demonstrate the successful operation of grid-forming controlled PV systems, highlighting their capability to influence power system frequency dynamics. The analysis underscores the significance of deloading PV operation in facilitating flexibility services provision, thereby enhancing the reliability and resilience of system operation.

Authors

Institutions

Publication Details

Published
2024-10-21
DOI
https://doi.org/10.1109/synergymed62435.2024.10799431
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid-Forming PV System for Frequency Ancillary Services Provision

Mathaios Panteli, Bojana Barać, Tomislav Capuder
Power Systems and Renewable Energy
article

Grid-Forming PV System for Frequency Ancillary Services Provision

Mathaios Panteli, Bojana Barać, Tomislav Capuder
article en

Abstract

With the increasing penetration of photovoltaic (PV) systems posing challenges to power system stability, this paper investigates the effectiveness of grid-forming controlled PV systems in providing frequency ancillary services. The study implements the Virtual Synchronous Machine strategy, utilizing DC-link capacitor energy for inertial response provision (DCVQVSM), integrated within a grid-forming topology. To ensure power-frequency droop control, an additional control loop is introduced within the DCVQ-VSM topology. The efficacy of this control system is proved through simulations conducted on a simple two-bus system and a fully-electrified active distribution network (ADN). Both case studies demonstrate the successful operation of grid-forming controlled PV systems, highlighting their capability to influence power system frequency dynamics. The analysis underscores the significance of deloading PV operation in facilitating flexibility services provision, thereby enhancing the reliability and resilience of system operation.

University of Zagreb (HR), University of Cyprus (CY)
Openalex Percentile: Top 76%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.