Dynamic Characteristics Analysis of 550 kV Fast Circuit Breaker Repulsion Valve

The conventional 550 kV circuit breaker operating mechanism has a long start-up time, which cannot meet the requirements for rapid disconnection. This paper proposes a design scheme for a fast circuit breaker operating mechanism using a repulsion valve, establishes a simulation model for the valve's motion characteristics, calculates the effects of structural parameters of the repulsion mechanism and excitation coil parameters on the dynamic characteristics of the fast valve, and obtains the design parameter configuration for the repulsion module. The research results show that the structural parameters of the repulsion mechanism and the excitation coil have a significant impact on the motion characteristics of the repulsion valve. By adopting a design scheme with a repulsion disc radius and excitation coil radius of 80 mm, a repulsion disc thickness of 10 mm, 30 turns of the excitation coil, an excitation coil thickness of 5 mm, and an initial air gap of 1 mm, the action times for single and dual repulsion mechanisms are 1.74 ms and 1.52 ms, respectively. Based on the simulation results, a prototype was developed, and a mechanical characteristic test platform was built. The measured start-up time of the new fast hydraulic operating mechanism is 2.59 ms. The research findings provide theoretical support for the development of the fast repulsion valve.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792616
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Characteristics Analysis of 550 kV Fast Circuit Breaker Repulsion Valve

Huancheng Zou, Zaixing Peng, Xin Lin, Bowen Xu et al.
Power Systems and Technologies
article

Dynamic Characteristics Analysis of 550 kV Fast Circuit Breaker Repulsion Valve

Huancheng Zou, Zaixing Peng, Xin Lin, Bowen Xu, Jianwei Wei
article en

Abstract

The conventional 550 kV circuit breaker operating mechanism has a long start-up time, which cannot meet the requirements for rapid disconnection. This paper proposes a design scheme for a fast circuit breaker operating mechanism using a repulsion valve, establishes a simulation model for the valve's motion characteristics, calculates the effects of structural parameters of the repulsion mechanism and excitation coil parameters on the dynamic characteristics of the fast valve, and obtains the design parameter configuration for the repulsion module. The research results show that the structural parameters of the repulsion mechanism and the excitation coil have a significant impact on the motion characteristics of the repulsion valve. By adopting a design scheme with a repulsion disc radius and excitation coil radius of 80 mm, a repulsion disc thickness of 10 mm, 30 turns of the excitation coil, an excitation coil thickness of 5 mm, and an initial air gap of 1 mm, the action times for single and dual repulsion mechanisms are 1.74 ms and 1.52 ms, respectively. Based on the simulation results, a prototype was developed, and a mechanical characteristic test platform was built. The measured start-up time of the new fast hydraulic operating mechanism is 2.59 ms. The research findings provide theoretical support for the development of the fast repulsion valve.

Shenyang University of Technology (CN), System Equipment (China) (CN), Xi’an Jiaotong-Liverpool University (CN)
Affordable and clean energy
Openalex Percentile: Top 78%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dynamic Characteristics Analysis of 550 kV Fast Circuit Breaker Repulsion Valve — Huancheng Zou, Zaixing Peng, et al. · (2024) | TGRS Research Map | TGRS