Evaluation and Optimization of the OLTC: Impact on the Contamination of the Dielectric Oil in the TP01 60/22 kV Transformer of the S.E Ingenio Huancavelica

The present research work focused on addressing the excess of on-load switch (OLTC) maneuvers in the TP01 Transformer of the Ingenio Huancavelica Substation from 2021 to 2023. This research used a quantitative, applied-type, quasi-experimental design approach, where one or more independent variables are manipulated to analyze the consequences on the dependent variable, pretest/posttest with a single group. The method used is an empirical method that is based on the knowledge and insight of the researcher. The results showed the reduction from 20 to 4 maneuvers per day, complying with the standards of the Technical Standard for the Quality of Electrical Services (NTCSE) of Peru. In addition, the level of dielectric oil contamination was mitigated from 15,742 ppm in August 2021 to 3,466 ppm in August 2023. In conclusion, the proper regulation of the Tapcon 230 Mr optimizes the control in the TP01 Transformer at the S.E. Ingenio, reducing daily maneuvers, improving operational efficiency.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1109/icpea63589.2024.10784692
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation and Optimization of the OLTC: Impact on the Contamination of the Dielectric Oil in the TP01 60/22 kV Transformer of the S.E Ingenio Huancavelica

R. Chavez, G. Rodríguez, Franklin Mael Alfaro Papuico, Ricardo Huamani Mayhua et al.
2 links
Power Transformer Diagnostics and Insulation
article

Evaluation and Optimization of the OLTC: Impact on the Contamination of the Dielectric Oil in the TP01 60/22 kV Transformer of the S.E Ingenio Huancavelica

R. Chavez, G. Rodríguez, Franklin Mael Alfaro Papuico, Ricardo Huamani Mayhua, César Ouisne Lonez
article en

Abstract

The present research work focused on addressing the excess of on-load switch (OLTC) maneuvers in the TP01 Transformer of the Ingenio Huancavelica Substation from 2021 to 2023. This research used a quantitative, applied-type, quasi-experimental design approach, where one or more independent variables are manipulated to analyze the consequences on the dependent variable, pretest/posttest with a single group. The method used is an empirical method that is based on the knowledge and insight of the researcher. The results showed the reduction from 20 to 4 maneuvers per day, complying with the standards of the Technical Standard for the Quality of Electrical Services (NTCSE) of Peru. In addition, the level of dielectric oil contamination was mitigated from 15,742 ppm in August 2021 to 3,466 ppm in August 2023. In conclusion, the proper regulation of the Tapcon 230 Mr optimizes the control in the TP01 Transformer at the S.E. Ingenio, reducing daily maneuvers, improving operational efficiency.

Universidad Continental (PE)
Clean water and sanitation
Openalex Percentile: Top 78%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.