Research on Movable Conditioning Test Method and Device Development of Vacuum Circuit Breaker for 40.5kV Capacitor Bank

The restrike of vacuum circuit breaker in capacitor bank seriously affects the reliable operation of reactive power compensation in power grid. High voltage and high current conditioning test can effectively improve the breaking capacity and stability and reduce the restrike rate. However, at present, the conditioning test is carried out on the circuit of the breaking test, which is complex and huge. It is difficult to configure for the manufacturing plant and the operation site, the quality of the factory conditioning is not good. Movable vacuum circuit breaker conditioning device become an urgent need for material acceptance and on-site operation and maintenance. In this paper, a movable conditioning test method and parameters are proposed, and a 40.5kV test device is developed. A capacitor discharge circuit is used for closing conditioning. By applying dynamic recovery voltages with different rise rates for no-load breaking, multiple restrikes are generated to perform breaking conditioning, and the anti-restrike performance is quantitatively evaluated according to the withstand recovery voltage level. Based on this, the first 40.5kV movable conditioning test detection device was developed and the effectiveness of device was verified. After the test, it was found that the contact surface was smooth, and there was a certain depth of melting spots evenly distributed, which further demonstrating the effectiveness of the device conditioning from the micro level. It shows that the movable device can be easily used for conditioning test and quantitative evaluation of anti-restrike performance in material acceptance, on-site operation and maintenance, ex-factory and other occasions.<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sup>

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792587
Primary Topic
Safety and Risk Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Movable Conditioning Test Method and Device Development of Vacuum Circuit Breaker for 40.5kV Capacitor Bank

Enyuan Dong, Ran Zhang, Yong Chen, Yongxing Wang et al.
Safety and Risk Management
article

Research on Movable Conditioning Test Method and Device Development of Vacuum Circuit Breaker for 40.5kV Capacitor Bank

Enyuan Dong, Ran Zhang, Yong Chen, Yongxing Wang, Yi Fan, Zhibing Li
article en

Abstract

The restrike of vacuum circuit breaker in capacitor bank seriously affects the reliable operation of reactive power compensation in power grid. High voltage and high current conditioning test can effectively improve the breaking capacity and stability and reduce the restrike rate. However, at present, the conditioning test is carried out on the circuit of the breaking test, which is complex and huge. It is difficult to configure for the manufacturing plant and the operation site, the quality of the factory conditioning is not good. Movable vacuum circuit breaker conditioning device become an urgent need for material acceptance and on-site operation and maintenance. In this paper, a movable conditioning test method and parameters are proposed, and a 40.5kV test device is developed. A capacitor discharge circuit is used for closing conditioning. By applying dynamic recovery voltages with different rise rates for no-load breaking, multiple restrikes are generated to perform breaking conditioning, and the anti-restrike performance is quantitatively evaluated according to the withstand recovery voltage level. Based on this, the first 40.5kV movable conditioning test detection device was developed and the effectiveness of device was verified. After the test, it was found that the contact surface was smooth, and there was a certain depth of melting spots evenly distributed, which further demonstrating the effectiveness of the device conditioning from the micro level. It shows that the movable device can be easily used for conditioning test and quantitative evaluation of anti-restrike performance in material acceptance, on-site operation and maintenance, ex-factory and other occasions.<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sup>

North China Electric Power University (CN), Dalian University of Technology (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 67%
Safety and Risk Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.