Research on Classification Evaluation Method of Capacitive Breaking Capacity of Vacuum Circuit Breaker

Vacuum circuit breaker has the advantages of small size, strong opening, closing ability and green environmental protection, is widely used in the switching of parallel reactive compensation capacitor banks in 35kV and below distribution network. Vacuum circuit breaker will produce pre-strike when shunt capacitor bank is switched, the high frequency arc will cause ablation and even fusion welding on the contact surface, which will affect the capacitive breaking performance. Therefore, it is great significance for the reliable operation of the distribution network to accurately evaluate the breaking capacity of the vacuum circuit breaker of the switching capacitor bank. Aiming at the reactive power compensation of capacitor banks, a classification evaluation method for capacitive opening and closing capacity of circuit breaker is proposed. By applying the dynamic recovery voltage to the vacuum circuit breaker when no load is broken, the strike occurs many times in the process of breaking, and the capacitive breaking ability of the circuit breaker is evaluated according to the drawn dielectric recovery characteristic curve. According to the test results of circuit breakers with different performance states, the breaking position parameters are determined, and the capacitive breaking capacity of vacuum circuit breaker is quantitatively evaluated. Through the breaking performance evaluation test of different design circuit breakers and the C2 class type test, the reasonable validity of the proposed method is verified from multiple dimensions through the comparison of test results.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792612
Citations
3
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Classification Evaluation Method of Capacitive Breaking Capacity of Vacuum Circuit Breaker

Dengkui Zhang, Enyuan Dong, Zhibing Li, Ran Zhang et al.
3 citations
Vacuum and Plasma Arcs
1.01
article

Research on Classification Evaluation Method of Capacitive Breaking Capacity of Vacuum Circuit Breaker

Dengkui Zhang, Enyuan Dong, Zhibing Li, Ran Zhang, Yongxing Wang, Qing-Kun Kong, Liyan Zhang
article en
3 citations

Abstract

Vacuum circuit breaker has the advantages of small size, strong opening, closing ability and green environmental protection, is widely used in the switching of parallel reactive compensation capacitor banks in 35kV and below distribution network. Vacuum circuit breaker will produce pre-strike when shunt capacitor bank is switched, the high frequency arc will cause ablation and even fusion welding on the contact surface, which will affect the capacitive breaking performance. Therefore, it is great significance for the reliable operation of the distribution network to accurately evaluate the breaking capacity of the vacuum circuit breaker of the switching capacitor bank. Aiming at the reactive power compensation of capacitor banks, a classification evaluation method for capacitive opening and closing capacity of circuit breaker is proposed. By applying the dynamic recovery voltage to the vacuum circuit breaker when no load is broken, the strike occurs many times in the process of breaking, and the capacitive breaking ability of the circuit breaker is evaluated according to the drawn dielectric recovery characteristic curve. According to the test results of circuit breakers with different performance states, the breaking position parameters are determined, and the capacitive breaking capacity of vacuum circuit breaker is quantitatively evaluated. Through the breaking performance evaluation test of different design circuit breakers and the C2 class type test, the reasonable validity of the proposed method is verified from multiple dimensions through the comparison of test results.

North China Electric Power University (CN), Dalian University of Technology (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 23%
Vacuum and Plasma Arcs
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.