Electromagnetic Radiation Test of Molded Case Circuit Breaker During Switching Operation

The molded case circuit breaker will generate instantaneous transient overvoltage and overcurrent during the switching operation, which will induce huge electric and magnetic fields, thereby interfering with the normal operation of secondary's intelligent devices of the circuit breaker. This paper aims to analyze the electromagnetic interference generated during the switching operation of molded case circuit breakers under different voltages, currents and phases. By collecting data of the electric field strength, magnetic field strength, arc voltage, and arc current generated by different experimental groups during switching operation, time-frequency characteristics analysis of the collected waveform data were carried out to obtain the distribution of electromagnetic interference frequency bands and characteristic energy. According to experimental results, the maximum electric field generated during the arcing process is 14.27kV/m, and the maximum magnetic field is 457A/m. These results provide basis for the formulation of electromagnetic compatibility test of the primary and secondary fusion devices.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792594
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electromagnetic Radiation Test of Molded Case Circuit Breaker During Switching Operation

Guanglin Sha, Caihong Zhao, Haoqing Wang, Ning Liu
1 links
Vacuum and Plasma Arcs
article

Electromagnetic Radiation Test of Molded Case Circuit Breaker During Switching Operation

Guanglin Sha, Caihong Zhao, Haoqing Wang, Ning Liu
article en

Abstract

The molded case circuit breaker will generate instantaneous transient overvoltage and overcurrent during the switching operation, which will induce huge electric and magnetic fields, thereby interfering with the normal operation of secondary's intelligent devices of the circuit breaker. This paper aims to analyze the electromagnetic interference generated during the switching operation of molded case circuit breakers under different voltages, currents and phases. By collecting data of the electric field strength, magnetic field strength, arc voltage, and arc current generated by different experimental groups during switching operation, time-frequency characteristics analysis of the collected waveform data were carried out to obtain the distribution of electromagnetic interference frequency bands and characteristic energy. According to experimental results, the maximum electric field generated during the arcing process is 14.27kV/m, and the maximum magnetic field is 457A/m. These results provide basis for the formulation of electromagnetic compatibility test of the primary and secondary fusion devices.

North China Electric Power University (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 78%
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electromagnetic Radiation Test of Molded Case Circuit Breaker During Switching Operation — Guanglin Sha, Caihong Zhao, et al. · (2024) | TGRS Research Map | TGRS