Research on Reducing the False Alarm Rate of External Breach Hazards in Online Monitoring System of Transmission Lines

In this paper, through the analysis of the false alarm rate of the transmission online monitoring system, 5 end factors were found and analysed one by one, and finally the 5 end factors of ‘ high percentage of non-sample library machinery ’, ‘ large error of the nearest point of the conductor picture and machinery ’, ‘ large tilt of the clasp ’ were identified, and a countermeasure table of the main causes was formulated by using the ‘ 5W1H method ’, and combined with the previous successful experience, based on the dimensions of the concealed site We established a sample library, constructed a three-dimensional model of the site, calculated the nearest point between the wire and the machinery, and adopted the movable buckle as a countermeasure, successfully reducing the false alarm rate from 75% to 35.78%. [9]–[10]

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1109/icpea63589.2024.10784637
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Reducing the False Alarm Rate of External Breach Hazards in Online Monitoring System of Transmission Lines

Jun Fan, Yi Cai, Zhongyan Liu, Weiwei Li et al.
Smart Grid and Power Systems
article

Research on Reducing the False Alarm Rate of External Breach Hazards in Online Monitoring System of Transmission Lines

Jun Fan, Yi Cai, Zhongyan Liu, Weiwei Li, Xiong Li
article en

Abstract

In this paper, through the analysis of the false alarm rate of the transmission online monitoring system, 5 end factors were found and analysed one by one, and finally the 5 end factors of ‘ high percentage of non-sample library machinery ’, ‘ large error of the nearest point of the conductor picture and machinery ’, ‘ large tilt of the clasp ’ were identified, and a countermeasure table of the main causes was formulated by using the ‘ 5W1H method ’, and combined with the previous successful experience, based on the dimensions of the concealed site We established a sample library, constructed a three-dimensional model of the site, calculated the nearest point between the wire and the machinery, and adopted the movable buckle as a countermeasure, successfully reducing the false alarm rate from 75% to 35.78%. [9]–[10]

State Grid Corporation of China (China) (CN)
Climate action
Openalex Percentile: Top 78%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Reducing the False Alarm Rate of External Breach Hazards in Online Monitoring System of Transmission Lines — Jun Fan, Yi Cai, et al. · (2024) | TGRS Research Map | TGRS