The Effects of Fault Current on the Post-Arc Dielectric Recovery of 500 V Low Voltage AC Fuses

When a fuse interrupts the fault current, the ability of the fuse to withstand the TRV without dielectric breakdown after current zero determines whether the interruption is successful or not. At present, there is relatively little research on the post-arc process of fuses, and the specific process of the post-arc dielectric recovery of fuses is not clear. In this paper, the post-arc dielectric recovery process of fuses with a rated voltage of 500VAC is experimentally investigated. The dielectric recovery is measured by applying a 1500 V DC voltage pulse to the fuse after current zero. It is found that when the fault current is 6.2 times the rated current, the dielectric recovery speed of the fuse is much slower than that of 35.4 times the rated current. Meanwhile, the experimental result has significant dispersity when the fault current is 6.2 times the rated current. The post-arc dielectric recovery strength of the fuse at 100us after current zero is analyzed, and the results show that the arc voltage and arcing time of the fuse are linearly related to the dielectric recovery strength. The shorter arcing time and the larger arc voltage lead to the higher dielectric recovery strength. Based on the analysis of experimental data and the observation of fulgurate, it is found that the reason for the dispersion of the dielectric recovery strength of fuses under overload current is the uneven arcing of the series-parallel restricted sections.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/icepe-st61894.2024.10792591
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effects of Fault Current on the Post-Arc Dielectric Recovery of 500 V Low Voltage AC Fuses

Yingsan Geng, Shawming Ma, Zhiyuan Liu, Jianhua Wang et al.
Electrical Fault Detection and Protection
article

The Effects of Fault Current on the Post-Arc Dielectric Recovery of 500 V Low Voltage AC Fuses

Yingsan Geng, Shawming Ma, Zhiyuan Liu, Jianhua Wang, Dongyu Wang, Bin Xiang, Huixin Du
article en

Abstract

When a fuse interrupts the fault current, the ability of the fuse to withstand the TRV without dielectric breakdown after current zero determines whether the interruption is successful or not. At present, there is relatively little research on the post-arc process of fuses, and the specific process of the post-arc dielectric recovery of fuses is not clear. In this paper, the post-arc dielectric recovery process of fuses with a rated voltage of 500VAC is experimentally investigated. The dielectric recovery is measured by applying a 1500 V DC voltage pulse to the fuse after current zero. It is found that when the fault current is 6.2 times the rated current, the dielectric recovery speed of the fuse is much slower than that of 35.4 times the rated current. Meanwhile, the experimental result has significant dispersity when the fault current is 6.2 times the rated current. The post-arc dielectric recovery strength of the fuse at 100us after current zero is analyzed, and the results show that the arc voltage and arcing time of the fuse are linearly related to the dielectric recovery strength. The shorter arcing time and the larger arc voltage lead to the higher dielectric recovery strength. Based on the analysis of experimental data and the observation of fulgurate, it is found that the reason for the dispersion of the dielectric recovery strength of fuses under overload current is the uneven arcing of the series-parallel restricted sections.

State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
State Key Laboratory of Electrical Insulation and Power Equipment
Affordable and clean energy
Openalex Percentile: Top 78%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Effects of Fault Current on the Post-Arc Dielectric Recovery of 500 V Low Voltage AC Fuses — Yingsan Geng, Shawming Ma, et al. · (2024) | TGRS Research Map | TGRS