A 97.3-dB SNR Bioimpedance AFE With −84-dB THD Segmented- ΔΣ M Sinusoidal Current Generator and Passing-Through Instrumentation Amplifier
This article presents a high-precision bioimpedance (BioZ) analog front end (AFE) to detect changes in tissue electrical properties as prognostic indicators for heart failure, cancer, and chronic pulmonary disease. To increase the BioZ measurement accuracy, this AFE achieves key technical improvements in three aspects: 1) a lookup table (LUT) with segmented delta-sigma modulator (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta \Sigma $ </tex-math></inline-formula>M) for area-efficient bit extension of the IDAC to produce low-distortion sinusoidal current; 2) a current amplifier (CA) and a passing-through instrumentation amplifier (PT-IA) to mitigate the 1/f noise modulation in current generator (CG) and readout, respectively; and 3) a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta \Sigma $ </tex-math></inline-formula>M ADC with tri-level dynamic element matching (TL-DEM) IDAC to achieve reference current noise cancellation while maintaining high linearity performance. Manufactured in a 0.18-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu $ </tex-math></inline-formula>m CMOS process, the overall AFE consumes 86.7–201.1 and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$54.8~{\mu }$ </tex-math></inline-formula>W, respectively, from the CG and readout. The CG achieves −84-dB total harmonic distortion (THD) and 170-pA/<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\surd $ </tex-math></inline-formula>Hz stimulating current at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$100~{\mu }$ </tex-math></inline-formula>Apk, while the AFE achieves 97.3-dB system signal-to-noise ratio (SNR) (BW <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$ = 4$ </tex-math></inline-formula> Hz) and 0.64-m<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Omega $ </tex-math></inline-formula>/<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\surd $ </tex-math></inline-formula>Hz sensitivity at 1 Hz. Impedance cardiography (ICG) has been successfully measured with dry electrodes.
Authors
- Zhiliang Hong (ORCID: https://orcid.org/0000-0002-7414-5654)
- Qinjing Pan (ORCID: https://orcid.org/0000-0001-7424-0865)
- Tianxiang Qu (ORCID: https://orcid.org/0000-0002-2244-736X)
- Jiawei Xu (ORCID: https://orcid.org/0000-0002-4150-0971)
- Li Xiao (ORCID: https://orcid.org/0000-0001-6172-9645)
- Min Chen (ORCID: https://orcid.org/0000-0002-7661-2455)
- Qi Luo (ORCID: https://orcid.org/0009-0001-4193-9837)
- Liheng Liu (ORCID: https://orcid.org/0000-0001-7084-3757)
Institutions
- Fudan University (CN)
Publication Details
- Journal
- IEEE Journal of Solid-State Circuits
- Published
- 2024-12-19
- DOI
- https://doi.org/10.1109/jssc.2024.3516040
- Citations
- 3
- Primary Topic
- Analog and Mixed-Signal Circuit Design
- Type
- article
- Field-Weighted Citation Impact
- 0.55
Funders
- National Key Research and Development Program of China