Study on High Jc and Low Loss Experimental NbTi/Cu0.5Mn/Cu Superconducting Wires for Accelerator Magnet in WST

With the development of Chinese medical industry, medical proton therapy instrument accelerator magnets were gradually developed to miniaturization, which puts forward high requirements for the performance of low loss NbTi superconducting wires. A new experimental structure of high critical current density and low loss NbTi/Cu0.5Mn/Cu superconducting wire has been developed in this paper. The microstructure and hardness of high purity oxygen-free copper and Cu-0.5%Mn alloy were characterized, and the resistivity at 300 K, 10 K and 4.2 K were compared. The resistivity of Cu-0.5%Mn alloy at 300 K, 10 K and 4.2 K is 3.8 µΩ·cm, 2.2 µΩ·cm and 2.2 µΩ·cm. The residual resistance ratio is only 1.7. The Cu-0.5%Mn alloy has a large resistance at low temperature, which could prevent the coupling between NbTi filament effectively. The experimental wire of Φ0.8 mm and 44 064 filaments was successfully prepared by a double stacking method. The filaments of the wire were uniformly deformed and the diameter of the filament was only 2.5 µm. With the increase of aging heat treatment times from 0 to 4 times, the critical current density increased from 492 A/mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> to 2615 A/mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> at 5 T&4.2 K. The critical current density of the wire has a weak correlation with the twist pitch of 14.7 mm to 5.3 mm. The hysteresis loss of the wire is 41.6 mJ/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> at ±3 T and the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$D_{eff}$</tex-math></inline-formula> is 2.62 µm. The RRR(300 K/10K) of the wire is more than 200, which could improve the thermal stability of the magnet and protect the magnet from quench.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2024-12-19
DOI
https://doi.org/10.1109/tasc.2024.3520085
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on High Jc and Low Loss Experimental NbTi/Cu0.5Mn/Cu Superconducting Wires for Accelerator Magnet in WST

Yaxue Wang, Pingxiang Zhang, Yanmin Zhu, W.J. Jia et al.
IEEE Transactions on Applied Superconductivity
Superconducting Materials and Applications
article

Study on High Jc and Low Loss Experimental NbTi/Cu0.5Mn/Cu Superconducting Wires for Accelerator Magnet in WST

Yaxue Wang, Pingxiang Zhang, Yanmin Zhu, W.J. Jia, Xianghong Liu, Ruilong Wang, Jian‐Feng Li, Yong Feng, Shufeng Yang, Zijing Zhou, Lingxiao Yan, Qiang Guo, Kailin Zhang, Shuai Wang, Wei Wang
article en

Abstract

With the development of Chinese medical industry, medical proton therapy instrument accelerator magnets were gradually developed to miniaturization, which puts forward high requirements for the performance of low loss NbTi superconducting wires. A new experimental structure of high critical current density and low loss NbTi/Cu0.5Mn/Cu superconducting wire has been developed in this paper. The microstructure and hardness of high purity oxygen-free copper and Cu-0.5%Mn alloy were characterized, and the resistivity at 300 K, 10 K and 4.2 K were compared. The resistivity of Cu-0.5%Mn alloy at 300 K, 10 K and 4.2 K is 3.8 µΩ·cm, 2.2 µΩ·cm and 2.2 µΩ·cm. The residual resistance ratio is only 1.7. The Cu-0.5%Mn alloy has a large resistance at low temperature, which could prevent the coupling between NbTi filament effectively. The experimental wire of Φ0.8 mm and 44 064 filaments was successfully prepared by a double stacking method. The filaments of the wire were uniformly deformed and the diameter of the filament was only 2.5 µm. With the increase of aging heat treatment times from 0 to 4 times, the critical current density increased from 492 A/mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> to 2615 A/mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> at 5 T&4.2 K. The critical current density of the wire has a weak correlation with the twist pitch of 14.7 mm to 5.3 mm. The hysteresis loss of the wire is 41.6 mJ/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> at ±3 T and the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$D_{eff}$</tex-math></inline-formula> is 2.62 µm. The RRR(300 K/10K) of the wire is more than 200, which could improve the thermal stability of the magnet and protect the magnet from quench.

IEEE Transactions on Applied SuperconductivityVol. 35(5)
Northwest Institute For Non-Ferrous Metal Research (CN), Western Metal Materials (China) (CN), University of Science and Technology Beijing (CN)
Openalex Percentile: Top 78%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.