Ultrasound-Activated Near-Infrared-II Afterglow Luminescence for Precise Cancer Imaging

Afterglow fluorescence imaging has been extensively assessed in ultrasensitive bioimaging. Since it eliminates the need for real-time excitation light and thereby circumvents the autofluorescence background of tissue, it holds tremendous potential in accurate biomedical imaging. However, current afterglow probes are rare and emit light only in the visible to near-infrared (NIR) range, which is inadequate for <i>in vivo</i> imaging. To resolve this issue, an ultrasound (US)-activated NIR-II afterglow luminescence probe (NPs-Ce4-SN) emitting afterglow luminescence with a peak at ∼1100 nm was developed. This peak is nearly 400 nm red-shifted compared with other reported afterglow probes. Of note, after US termination, NPs-Ce4-SN undergoes energy transformation to produce <sup>1</sup>O<sub>2</sub> and subsequently undergoes internal oxidation-reduction reaction to produce NIR-II afterglow, generating high signal-to-noise ratio and high-penetration depth imaging. <i>In vitro</i> and <i>in vivo</i> NIR-II afterglow imaging experiments revealed that NPs-Ce4-SN has good biocompatibility and deep tissue penetration depth, suggesting a diagnostic strategy for <i>in vivo</i> tumor imaging with a high signal-to-noise ratio.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2024-12-19
DOI
https://doi.org/10.1021/acsabm.4c01352
Citations
8
Primary Topic
Nanoplatforms for cancer theranostics
Type
article
Field-Weighted Citation Impact
1.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound-Activated Near-Infrared-II Afterglow Luminescence for Precise Cancer Imaging

Jibin Song, Ying Wu, Lichao Su, Meng Yuan et al.
8 citations
ACS Applied Bio Materials
Nanoplatforms for cancer theranostics
1.48
article

Ultrasound-Activated Near-Infrared-II Afterglow Luminescence for Precise Cancer Imaging

Jibin Song, Ying Wu, Lichao Su, Meng Yuan, Shi Gao, Xiaoguang Ge, Wenzheng Liu, Xiao Fang
article en
8 citations

Abstract

Afterglow fluorescence imaging has been extensively assessed in ultrasensitive bioimaging. Since it eliminates the need for real-time excitation light and thereby circumvents the autofluorescence background of tissue, it holds tremendous potential in accurate biomedical imaging. However, current afterglow probes are rare and emit light only in the visible to near-infrared (NIR) range, which is inadequate for <i>in vivo</i> imaging. To resolve this issue, an ultrasound (US)-activated NIR-II afterglow luminescence probe (NPs-Ce4-SN) emitting afterglow luminescence with a peak at ∼1100 nm was developed. This peak is nearly 400 nm red-shifted compared with other reported afterglow probes. Of note, after US termination, NPs-Ce4-SN undergoes energy transformation to produce <sup>1</sup>O<sub>2</sub> and subsequently undergoes internal oxidation-reduction reaction to produce NIR-II afterglow, generating high signal-to-noise ratio and high-penetration depth imaging. <i>In vitro</i> and <i>in vivo</i> NIR-II afterglow imaging experiments revealed that NPs-Ce4-SN has good biocompatibility and deep tissue penetration depth, suggesting a diagnostic strategy for <i>in vivo</i> tumor imaging with a high signal-to-noise ratio.

ACS Applied Bio MaterialsVol. 8(1)
Jilin University (CN), Peking University (CN), Peking University Third Hospital (CN), Union Hospital (CN), Fujian Agriculture and Forestry University (CN), Beijing University of Chemical Technology (CN), Fuzhou University (CN)
Openalex Percentile: Top 19%
Nanoplatforms for cancer theranostics
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ultrasound-Activated Near-Infrared-II Afterglow Luminescence for Precise Cancer Imaging — Jibin Song, Ying Wu, et al. · ACS Applied Bio Materials (2024) | TGRS Research Map | TGRS