Super-Resolved Fluorescence Lifetime Imaging of Single Cy3 Molecules and Quantum Dots Using Time-Correlated Single Photon Counting with a Four-Pixel Fiber Optic Array Camera

Time-resolved single molecule localization microscopy (TR-SMLM) with a 2 × 2 pixel fiber optic array camera was combined with time-correlated single photon counting (TCSPC) to obtain super-resolved fluorescence lifetime images of individual Cy3 dye molecules and individual colloidal CdSe/CdS/ZnS core/shell/shell semiconductor quantum dots (QDs). The characteristic blinking and bleaching behavior of the Cy3 and the blinking behavior of the QD emitters were used as distinguishing optical characteristics to isolate them and determine their centroid locations with spatial resolution below the optical diffraction limit. TCSPC was used to characterize the fluorescence lifetime and intensity corresponding to each emitter location. The mean centroid locations of the QDs could be determined with a precision of ∼1-4 nm, and the mean centroid locations of the Cy3 molecules could be determined with a precision of ∼2-9 nm, depending on the number of photons collected during the observation time. In a super-resolved fluorescence lifetime image with a single Cy3 dye molecule and a single QD separated by ∼34 nm, the two emitters were distinguished based on the average photon arrival times with respect to the excitation laser pulse observed during time intervals when only one emitter was in the on state, ∼6 ns for Cy3 and ∼17 ns for the QD. The mean distance between the two emitters was determined with a precision of ∼8 nm. The feasibility of using this super-resolved fluorescence lifetime imaging technique to investigate QD-dye complexes that use Förster resonance energy transfer (FRET) and/or electron transfer to form optical biosensors is discussed.

Authors

Institutions

Publication Details

Journal
The Journal of Physical Chemistry A
Published
2024-12-19
DOI
https://doi.org/10.1021/acs.jpca.4c05143
Citations
2
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
1.32

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Super-Resolved Fluorescence Lifetime Imaging of Single Cy3 Molecules and Quantum Dots Using Time-Correlated Single Photon Counting with a Four-Pixel Fiber Optic Array Camera

Martin P. Gelfand, Igor L. Medintz, Christopher M. Green, James H. Werner et al.
2 citations
The Journal of Physical Chemistry A
Advanced Fluorescence Microscopy Techniques
1.32
article

Super-Resolved Fluorescence Lifetime Imaging of Single Cy3 Molecules and Quantum Dots Using Time-Correlated Single Photon Counting with a Four-Pixel Fiber Optic Array Camera

Martin P. Gelfand, Igor L. Medintz, Christopher M. Green, James H. Werner, Megan K. Dunlap, Michael H. Stewart, Alan Van Orden, Sebastián A. Dı́az, Liam A. Koch, Peter M. Goodwin, Duncan P. Ryan, Kimihiro Susumu
article en
2 citations

Abstract

Time-resolved single molecule localization microscopy (TR-SMLM) with a 2 × 2 pixel fiber optic array camera was combined with time-correlated single photon counting (TCSPC) to obtain super-resolved fluorescence lifetime images of individual Cy3 dye molecules and individual colloidal CdSe/CdS/ZnS core/shell/shell semiconductor quantum dots (QDs). The characteristic blinking and bleaching behavior of the Cy3 and the blinking behavior of the QD emitters were used as distinguishing optical characteristics to isolate them and determine their centroid locations with spatial resolution below the optical diffraction limit. TCSPC was used to characterize the fluorescence lifetime and intensity corresponding to each emitter location. The mean centroid locations of the QDs could be determined with a precision of ∼1-4 nm, and the mean centroid locations of the Cy3 molecules could be determined with a precision of ∼2-9 nm, depending on the number of photons collected during the observation time. In a super-resolved fluorescence lifetime image with a single Cy3 dye molecule and a single QD separated by ∼34 nm, the two emitters were distinguished based on the average photon arrival times with respect to the excitation laser pulse observed during time intervals when only one emitter was in the on state, ∼6 ns for Cy3 and ∼17 ns for the QD. The mean distance between the two emitters was determined with a precision of ∼8 nm. The feasibility of using this super-resolved fluorescence lifetime imaging technique to investigate QD-dye complexes that use Förster resonance energy transfer (FRET) and/or electron transfer to form optical biosensors is discussed.

The Journal of Physical Chemistry AVol. 129(1)
United States Naval Research Laboratory (US), Los Alamos National Laboratory (US), Optical Sciences (United States) (US), Center for Integrated Nanotechnologies (US), Colorado State University (US)
American Chemical Society Petroleum Research Fund, Office of Naval Research, Laboratory Directed Research and Development, U.S. Naval Research Laboratory, Los Alamos National Laboratory
Affordable and clean energy
Openalex Percentile: Top 14%
Advanced Fluorescence Microscopy Techniques
1.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.