The TOTEM nT2 detector: architecture, operation and performance

The TOTEM experiment at the LHC has produced a large set of measurements on diffractive processes and pp cross sections. A new detector, called nT2, has been designed to measure the inelastic scattering rate during the LHC special run of 2023. Due to the high radiation environment, the detector had to be installed in 10-20 minutes at most, then commissioned and operated after only few days. The detector, based on plastic scintillators read out by matrices of SiPMs, was designed with such constraints in mind. The front-end, DAQ and control electronics was developed with a fault tolerant architecture, moving as many functionalities as possible on a radiation tolerant SoC FPGA, hosting an integrated ARM controller. Here we will describe the nT2 detector and its read-out and control electronics. The detector was successfully operated during the special run: we will report the preliminary results on the detector performance.

Authors

Institutions

Publication Details

Published
2024-12-17
DOI
https://doi.org/10.22323/1.476.0914
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The TOTEM nT2 detector: architecture, operation and performance

Edoardo Bossini
Particle Detector Development and Performance
article

The TOTEM nT2 detector: architecture, operation and performance

Edoardo Bossini
article en

Abstract

The TOTEM experiment at the LHC has produced a large set of measurements on diffractive processes and pp cross sections. A new detector, called nT2, has been designed to measure the inelastic scattering rate during the LHC special run of 2023. Due to the high radiation environment, the detector had to be installed in 10-20 minutes at most, then commissioned and operated after only few days. The detector, based on plastic scintillators read out by matrices of SiPMs, was designed with such constraints in mind. The front-end, DAQ and control electronics was developed with a fault tolerant architecture, moving as many functionalities as possible on a radiation tolerant SoC FPGA, hosting an integrated ARM controller. Here we will describe the nT2 detector and its read-out and control electronics. The detector was successfully operated during the special run: we will report the preliminary results on the detector performance.

Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (IT)
Sustainable cities and communities
Openalex Percentile: Top 93%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.