Colorimetry-based quantification of protein droplets using "ImageJ"

The objective of this study is to analyze protein concentration on a colorimetric basis by utilizing the openly accessible 'ImageJ' software. We herein report the successful measurement of protein concentration on a parafilm surface, following the application of Bradford reagent and subsequent photography with a smartphone, followed by analysis using the ImageJ software. Ovalbumin (OVA) and bovine serum albumin (BSA) were dissolved in phosphate buffered saline (PBS) and used as standards. The results demonstrated a linear correlation between integrated density and the actual weight of the standard, with R² values of 0.9908 for OVA samples in the range of 0-1.5 mg/ml and 0.9781 for BSA in the range of 0.25-1.5 mg/ml. The straightforward nature of the experiments and analyses makes the study we present here an invaluable resource for researchers and students who are constrained by equipment limitations, such as the lack of access to spectrophotometers.

Authors

Publication Details

Journal
GSC Biological and Pharmaceutical Sciences
Published
2024-11-30
DOI
https://doi.org/10.30574/gscbps.2024.29.2.0426
Citations
2
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Colorimetry-based quantification of protein droplets using "ImageJ"

Djoko Kisworo, Sulaiman Ngongu Depamede
2 citations
GSC Biological and Pharmaceutical Sciences
Metabolomics and Mass Spectrometry Studies
0.47
article

Colorimetry-based quantification of protein droplets using "ImageJ"

Djoko Kisworo, Sulaiman Ngongu Depamede
article en
2 citations

Abstract

The objective of this study is to analyze protein concentration on a colorimetric basis by utilizing the openly accessible 'ImageJ' software. We herein report the successful measurement of protein concentration on a parafilm surface, following the application of Bradford reagent and subsequent photography with a smartphone, followed by analysis using the ImageJ software. Ovalbumin (OVA) and bovine serum albumin (BSA) were dissolved in phosphate buffered saline (PBS) and used as standards. The results demonstrated a linear correlation between integrated density and the actual weight of the standard, with R² values of 0.9908 for OVA samples in the range of 0-1.5 mg/ml and 0.9781 for BSA in the range of 0.25-1.5 mg/ml. The straightforward nature of the experiments and analyses makes the study we present here an invaluable resource for researchers and students who are constrained by equipment limitations, such as the lack of access to spectrophotometers.

GSC Biological and Pharmaceutical SciencesVol. 29(2)
Openalex Percentile: Top 33%
Metabolomics and Mass Spectrometry Studies
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.