Status of the kilogram realisation using the XRCD method at PTB

Since the establishment of the revised SI the unit of mass, the kilogram, can be realised by two primary methods based on Planck's constant - the “Kibble balances” and the “XRCD” method (X-ray crystal density). The XRCD method is based on a high-quality characterisation of spheres made of isotopically enriched 28 Si silicon, which can be divided into two main activities, the determination of crystal/material parameters and the determination of the macroscopic volume of 28 Si spheres and their surface layers. This subdivision is of particular interest since the material parameters are considered constant and are not re-determined when the realisation is “reactivated”. Before and after the redefinition of the kilogram, comparisons of the most accurate realisation experiments were carried out. This publication discusses the parameters, methodology and instrumentation used by PTB for the participation in CCM.R-kg-P1 (Pilot Study) before redefinition in comparison to the results of the experiments for the participation in CCM.M-K8.2019 and CCM.M-K8.2021 after redefinition.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-19
DOI
https://doi.org/10.1016/j.measen.2024.101353
Citations
2
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Status of the kilogram realisation using the XRCD method at PTB

Michael Borys, Dorothea Knopf, Arnold Nicolaus, Matthias Müller et al.
2 citations
Measurement Sensors
Scientific Measurement and Uncertainty Evaluation
0.92
article

Status of the kilogram realisation using the XRCD method at PTB

Michael Borys, Dorothea Knopf, Arnold Nicolaus, Matthias Müller, Eva Kühn, Daniela Eppers, H. Bettin
article en
2 citations

Abstract

Since the establishment of the revised SI the unit of mass, the kilogram, can be realised by two primary methods based on Planck's constant - the “Kibble balances” and the “XRCD” method (X-ray crystal density). The XRCD method is based on a high-quality characterisation of spheres made of isotopically enriched 28 Si silicon, which can be divided into two main activities, the determination of crystal/material parameters and the determination of the macroscopic volume of 28 Si spheres and their surface layers. This subdivision is of particular interest since the material parameters are considered constant and are not re-determined when the realisation is “reactivated”. Before and after the redefinition of the kilogram, comparisons of the most accurate realisation experiments were carried out. This publication discusses the parameters, methodology and instrumentation used by PTB for the participation in CCM.R-kg-P1 (Pilot Study) before redefinition in comparison to the results of the experiments for the participation in CCM.M-K8.2019 and CCM.M-K8.2021 after redefinition.

Measurement SensorsVol. 38
Physikalisch-Technische Bundesanstalt (DE)
Openalex Percentile: Top 19%
Scientific Measurement and Uncertainty Evaluation
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.