Cropland observatory nodes (CRONOS): Proximal, integrated soil-plant-atmosphere monitoring systems

Soil-plant-atmosphere conditions in crop fields can differ substantially from those at the nearest weather station, creating uncertainty in crop management decisions and scientific analyses. To reduce this uncertainty, CRopland Observatory NOdeS (CRONOS) were developed to monitor soil water content, green canopy cover (GCC), and atmospheric conditions in crop fields. Here we evaluate the accuracy and reliability of first-generation CRONOS systems and compare CRONOS data to data from the nearest permanent weather station. CRONOS stations were installed in three winter wheat ( Triticum aestivum ) fields across Oklahoma, USA. Each was equipped with a cosmic-ray neutron sensor to measure soil water content, a camera to monitor GCC, and an all-in-one weather station. Validation sampling showed that CRONOS stations accurately determined field-scale average soil water content, with a mean absolute difference (MAD) of 0.025 cm 3 cm -3 and a Nash-Sutcliffe Efficiency (NSE) of 0.742. Greater discrepancies existed between CRONOS GCC estimates and field-scale average GCC, with an MAD of 11% and NSE of 0.67. There was generally strong agreement between CRONOS atmospheric data and data from a collocated, high quality weather station, with NSE values ≥ 0.95 for measurements of air temperature and atmospheric pressure, but slightly poorer agreement for precipitation, solar radiation, relative humidity, and wind speed (NSE values ≥ 0.73). The reliability of the CRONOS cameras needs to be improved because 43% of the scheduled images were missing or unsuitable for GCC analysis, but the reliability of the other sensors was high with ≥ 98% valid observations. Overall, CRONOS stations show good potential to improve monitoring of the soil-plant-atmosphere continuum in cropland.

Authors

Institutions

Publication Details

Journal
Smart Agricultural Technology
Published
2024-12-19
DOI
https://doi.org/10.1016/j.atech.2024.100737
Primary Topic
Soil Moisture and Remote Sensing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cropland observatory nodes (CRONOS): Proximal, integrated soil-plant-atmosphere monitoring systems

Andres Patrignani, Erik S. Krueger, Tyson E. Ochsner, D. Cole Diggins et al.
Smart Agricultural Technology
Soil Moisture and Remote Sensing
article

Cropland observatory nodes (CRONOS): Proximal, integrated soil-plant-atmosphere monitoring systems

Andres Patrignani, Erik S. Krueger, Tyson E. Ochsner, D. Cole Diggins, William G. Brown
article en

Abstract

Soil-plant-atmosphere conditions in crop fields can differ substantially from those at the nearest weather station, creating uncertainty in crop management decisions and scientific analyses. To reduce this uncertainty, CRopland Observatory NOdeS (CRONOS) were developed to monitor soil water content, green canopy cover (GCC), and atmospheric conditions in crop fields. Here we evaluate the accuracy and reliability of first-generation CRONOS systems and compare CRONOS data to data from the nearest permanent weather station. CRONOS stations were installed in three winter wheat ( Triticum aestivum ) fields across Oklahoma, USA. Each was equipped with a cosmic-ray neutron sensor to measure soil water content, a camera to monitor GCC, and an all-in-one weather station. Validation sampling showed that CRONOS stations accurately determined field-scale average soil water content, with a mean absolute difference (MAD) of 0.025 cm 3 cm -3 and a Nash-Sutcliffe Efficiency (NSE) of 0.742. Greater discrepancies existed between CRONOS GCC estimates and field-scale average GCC, with an MAD of 11% and NSE of 0.67. There was generally strong agreement between CRONOS atmospheric data and data from a collocated, high quality weather station, with NSE values ≥ 0.95 for measurements of air temperature and atmospheric pressure, but slightly poorer agreement for precipitation, solar radiation, relative humidity, and wind speed (NSE values ≥ 0.73). The reliability of the CRONOS cameras needs to be improved because 43% of the scheduled images were missing or unsuitable for GCC analysis, but the reliability of the other sensors was high with ≥ 98% valid observations. Overall, CRONOS stations show good potential to improve monitoring of the soil-plant-atmosphere continuum in cropland.

Smart Agricultural TechnologyVol. 10
Oklahoma State University (US), Kansas State University (US)
Openalex Percentile: Top 79%
Soil Moisture and Remote Sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.