Evaluating the Utilization of the National Cancer Institute Computed Tomography Program for Calculating Size-specific Dose Estimate and Effective Dose in Computed Tomography in Thai Pediatric Patients

The objectives of this study were to assess the feasibility of utilizing computational calculations and the simulation of the National Cancer Institute computed tomography (NCICT) dosimetry system to obtain size-specific dose estimate (SSDE) and effective dose values resulting from the most common CT examinations in Thai pediatric patients and to evaluate age- and size-specific k conversion factor. For the calculation methods, SSDEs were calculated using the American Association of Physicists in Medicine Report No. 220 and 293 methodologies. The results revealed that SSDEs derived from CT scans of the body, obtained through the two different methods, varied by within 10%. The size of the patient and the scanning distance had an impact on the variability of E values derived from NCICT. Age- and size-specific k conversion factors may be used as a first line to estimate risk for the pediatric patients.

Authors

Institutions

Publication Details

Journal
Journal of Medical Physics
Published
2024-10-01
DOI
https://doi.org/10.4103/jmp.jmp_49_24
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Utilization of the National Cancer Institute Computed Tomography Program for Calculating Size-specific Dose Estimate and Effective Dose in Computed Tomography in Thai Pediatric Patients

Supawitoo Sookpeng, C J Martin, Natch Rattanarungruangchai, M. Rosario López-Gonzalez
1 links
Journal of Medical Physics
Radiation Dose and Imaging
article

Evaluating the Utilization of the National Cancer Institute Computed Tomography Program for Calculating Size-specific Dose Estimate and Effective Dose in Computed Tomography in Thai Pediatric Patients

Supawitoo Sookpeng, C J Martin, Natch Rattanarungruangchai, M. Rosario López-Gonzalez
article en

Abstract

The objectives of this study were to assess the feasibility of utilizing computational calculations and the simulation of the National Cancer Institute computed tomography (NCICT) dosimetry system to obtain size-specific dose estimate (SSDE) and effective dose values resulting from the most common CT examinations in Thai pediatric patients and to evaluate age- and size-specific k conversion factor. For the calculation methods, SSDEs were calculated using the American Association of Physicists in Medicine Report No. 220 and 293 methodologies. The results revealed that SSDEs derived from CT scans of the body, obtained through the two different methods, varied by within 10%. The size of the patient and the scanning distance had an impact on the variability of E values derived from NCICT. Age- and size-specific k conversion factors may be used as a first line to estimate risk for the pediatric patients.

Journal of Medical PhysicsVol. 49(4)
Naresuan University (TH), University of Glasgow (GB)
Thailand Institute of Nuclear Technology
Good health and well-being
Openalex Percentile: Top 60%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating the Utilization of the National Cancer Institute Computed Tomography Program for Calculating Size-specific Dose Estimate and Effective Dose in Computed Tomography in Thai Pediatric Patients — Supawitoo Sookpeng, C J Martin, et al. · Journal of Medical Physics (2024) | TGRS Research Map | TGRS