Evaluation of Hydrogen Embrittlement of Three Aluminum Alloys by Three-Point Bending Test Affected by Three Types of Plating
Hydrogen embrittlement affected by three types of plating (low-P and high-P types electroless Ni-P plating and electrolytic zinc plating) was investigated by means of slow-strain-rate three-point bending test on three aluminum alloys (2017-T3, 6061-T6 and 7075-T651). Hydrogen generated by the Ni-P and zinc plating was absorbed in the aluminum alloy substrates, and the trap sites in the aluminum alloy substrates for the absorbed hydrogen differed between Ni-P and zinc plating. Hydrogen embrittlement was able to be evaluated by the three-point bending tests on plated aluminum alloys. Zinc plating did not cause embrittlement for all the alloys, but Ni-P plating induced embrittlement only for the 6061-T6 aluminum alloy. The result of embrittlement of the Ni-P plated 6061-T6 aluminum alloy corresponds to the highest amount of hydrogen desorbed below 240°C than the other alloys.
Authors
- Yukinori Oda
- Kota Kawaue
- Keitaro Horikawa (ORCID: https://orcid.org/0000-0003-4573-9952)
- Ryoichi Kuwano
- Teruto Kanadani
- Makoto Hino
Institutions
- Okayama University of Science (JP)
- Hiroshima Institute of Technology (JP)
- Nomura Holdings (Japan) (JP)
- The University of Osaka (JP)
Publication Details
- Journal
- MATERIALS TRANSACTIONS
- Published
- 2024-12-19
- DOI
- https://doi.org/10.2320/matertrans.mt-l2024009
- Citations
- 3
- Primary Topic
- Hydrogen embrittlement and corrosion behaviors in metals
- Type
- article
- Field-Weighted Citation Impact
- 0.52
Funders
- Light Metal Educational Foundation