What is the minimum time interval for reporting of intraoperative core body temperature measurements in pediatric anesthesia? A secondary analysis

Given that perioperative normothermia represents a quality parameter in pediatric anesthesia, numerous studies have been conducted on temperature measurement, albeit with heterogeneous measurement intervals, ranging from 30 s to fifteen minutes. We aimed to determine the minimum time interval for reporting of intraoperative core body temperature across commonly used measurement intervals in children. Data were extracted from the records of 65 children who had participated in another clinical study and analyzed using a quasibinomial mixed linear model. Documented artifacts, like probe dislocations or at the end of anesthesia, were removed. Primary outcome was the respective probability of failing to detect a temperature change of 0.2 °C or more at any one measurement point at 30 s, one minute, two minutes, five minutes, ten minutes, and fifteen minutes, considering an expected probability of less than 5% to be acceptable. Secondary outcomes included the probabilities of failing to detect hypothermia (< 36.0 °C) and hyperthermia (> 38.0 °C). Following the removal of 4,909 exclusions, the remaining 222,366 timestamped measurements (representing just over 60 h of monitoring) were analyzed. The median measurement time was 45 min. The expected probabilities of failing to detect a temperature change of 0.2 °C or more were 0.2% [95%-CI 0.0-0.7], 0.5% [95%-CI 0.0-1.2], 1.5% [95%-CI 0.2-2.6], 4.8% [95%-CI 2.7-6.9], 22.4% [95%-CI 18.3-26.4], and 31.9% [95%-CI 27.3-36.4], respectively. Probabilities for the detection of hyperthermia (n = 9) were lower and omitted for hypothermia due to low prevalence (n = 1). In conclusion, the core body temperature should be reported at intervals of no more than five minutes to ensure the detection of any temperature change in normothermic ranges. Further studies should focus on hypothermic and hyperthermic ranges.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Monitoring and Computing
Published
2024-12-19
DOI
https://doi.org/10.1007/s10877-024-01254-y
Citations
1
Primary Topic
Thermal Regulation in Medicine
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

What is the minimum time interval for reporting of intraoperative core body temperature measurements in pediatric anesthesia? A secondary analysis

Clemens Miller, Marcus Nemeth, Johannes Wieditz, Anselm Bräuer
1 citations
Journal of Clinical Monitoring and Computing
Thermal Regulation in Medicine
0.42
article

What is the minimum time interval for reporting of intraoperative core body temperature measurements in pediatric anesthesia? A secondary analysis

Clemens Miller, Marcus Nemeth, Johannes Wieditz, Anselm Bräuer
article en
1 citations

Abstract

Given that perioperative normothermia represents a quality parameter in pediatric anesthesia, numerous studies have been conducted on temperature measurement, albeit with heterogeneous measurement intervals, ranging from 30 s to fifteen minutes. We aimed to determine the minimum time interval for reporting of intraoperative core body temperature across commonly used measurement intervals in children. Data were extracted from the records of 65 children who had participated in another clinical study and analyzed using a quasibinomial mixed linear model. Documented artifacts, like probe dislocations or at the end of anesthesia, were removed. Primary outcome was the respective probability of failing to detect a temperature change of 0.2 °C or more at any one measurement point at 30 s, one minute, two minutes, five minutes, ten minutes, and fifteen minutes, considering an expected probability of less than 5% to be acceptable. Secondary outcomes included the probabilities of failing to detect hypothermia (< 36.0 °C) and hyperthermia (> 38.0 °C). Following the removal of 4,909 exclusions, the remaining 222,366 timestamped measurements (representing just over 60 h of monitoring) were analyzed. The median measurement time was 45 min. The expected probabilities of failing to detect a temperature change of 0.2 °C or more were 0.2% [95%-CI 0.0-0.7], 0.5% [95%-CI 0.0-1.2], 1.5% [95%-CI 0.2-2.6], 4.8% [95%-CI 2.7-6.9], 22.4% [95%-CI 18.3-26.4], and 31.9% [95%-CI 27.3-36.4], respectively. Probabilities for the detection of hyperthermia (n = 9) were lower and omitted for hypothermia due to low prevalence (n = 1). In conclusion, the core body temperature should be reported at intervals of no more than five minutes to ensure the detection of any temperature change in normothermic ranges. Further studies should focus on hypothermic and hyperthermic ranges.

Journal of Clinical Monitoring and ComputingVol. 39(5)
Behandlungszentrum Aschau (DE), University of Göttingen (DE)
Openalex Percentile: Top 32%
Thermal Regulation in Medicine
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.