Exploring the performance of a DOI-capable TOF-PET module using different SiPMs, customized and commercial readout electronics

<i>Objective.</i>Time resolution is crucial in positron emission tomography (PET) to enhance the signal-to-noise ratio and image quality. Moreover, high sensitivity requires long scintillators, which can cause distortions in the reconstructed images due to parallax effects. This study evaluates the performance of a time-of-flight (TOF)-PET module that makes use of a single-side readout of a4×43.1×3.1×15mm<sup>3</sup>LYSO:Ce matrix with an array of4×4silicon photomultipliers (SiPMs) and a light guide to extract high-resolution TOF and depth of interaction (DOI) information.<i>Approach.</i>This study assesses the performance of the detector prototype using the commercially available TOFPET2 ASIC and SiPMs from various producers. DOI and TOF performance are compared to results using custom-made NINO 32-chip based electronics.<i>Main results.</i>Using a Broadcom NUV-MT array, the detector module read out by the TOFPET2 ASIC demonstrates a DOI resolution of 2.6 ± 0.2 mm full width at half maximum (FWHM) and a coincidence time resolution (CTR) of 216 ± 6 ps FWHM. When read out using the NINO 32-chip based electronics, the same module achieves a DOI resolution of 2.5 ± 0.2 mm and a CTR of 170 ± 5 ps.<i>Significance.</i>The prototype module, read out by commercial electronics and using state-of-the-art SiPMs, achieves a DOI performance comparable to that obtained with custom-made electronics and a CTR of around 200 ps. This approach is scalable to thousands of channels, with only a deterioration in timing resolution compared to the custom-made electronics, which achieve a CTR of 140 ps using a standard non-DOI module.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-12-19
DOI
https://doi.org/10.1088/1361-6560/ada19a
Citations
3
Primary Topic
Semiconductor materials and devices
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring the performance of a DOI-capable TOF-PET module using different SiPMs, customized and commercial readout electronics

Giulia Terragni, E. Auffray, Johann Marton, M. Pizzichemi et al.
3 citations
Physics in Medicine and Biology
Semiconductor materials and devices
0.63
article

Exploring the performance of a DOI-capable TOF-PET module using different SiPMs, customized and commercial readout electronics

Giulia Terragni, E. Auffray, Johann Marton, M. Pizzichemi, S. Gundacker, Vanessa Nadig, Volkmar Schulz, E. Tribbia, Ekaterini Toumparidou, T. Meyer, Stefano di Gangi
article en
3 citations

Abstract

<i>Objective.</i>Time resolution is crucial in positron emission tomography (PET) to enhance the signal-to-noise ratio and image quality. Moreover, high sensitivity requires long scintillators, which can cause distortions in the reconstructed images due to parallax effects. This study evaluates the performance of a time-of-flight (TOF)-PET module that makes use of a single-side readout of a4×43.1×3.1×15mm<sup>3</sup>LYSO:Ce matrix with an array of4×4silicon photomultipliers (SiPMs) and a light guide to extract high-resolution TOF and depth of interaction (DOI) information.<i>Approach.</i>This study assesses the performance of the detector prototype using the commercially available TOFPET2 ASIC and SiPMs from various producers. DOI and TOF performance are compared to results using custom-made NINO 32-chip based electronics.<i>Main results.</i>Using a Broadcom NUV-MT array, the detector module read out by the TOFPET2 ASIC demonstrates a DOI resolution of 2.6 ± 0.2 mm full width at half maximum (FWHM) and a coincidence time resolution (CTR) of 216 ± 6 ps FWHM. When read out using the NINO 32-chip based electronics, the same module achieves a DOI resolution of 2.5 ± 0.2 mm and a CTR of 170 ± 5 ps.<i>Significance.</i>The prototype module, read out by commercial electronics and using state-of-the-art SiPMs, achieves a DOI performance comparable to that obtained with custom-made electronics and a CTR of around 200 ps. This approach is scalable to thousands of channels, with only a deterioration in timing resolution compared to the custom-made electronics, which achieve a CTR of 140 ps using a standard non-DOI module.

Physics in Medicine and BiologyVol. 70(2)
University of Vienna (AT), University of Milano-Bicocca (IT), European Organization for Nuclear Research (CH), RWTH Aachen University (DE)
Openalex Percentile: Top 30%
Semiconductor materials and devices
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.