A comparative study of experimental and simulated ultrasound beam propagation through cranial bones

<i>Objective.</i>Transcranial ultrasound is used in a variety of treatments, including neuromodulation, opening the blood-brain barrier, and high intensity focused ultrasound therapies. To ensure safety and efficacy of these treatments, numerical simulations of the ultrasound field within the brain are used for treatment planning and evaluation. This study investigates the accuracy of numerical modelling of the propagation of focused ultrasound through cranial bones.<i>Approach.</i>Holograms of acoustic fields after propagation through four human skull specimens were measured for frequencies ranging from 270 kHz to 1 MHz, using both quasi-continuous and pulsed modes. The open-source k-Wave toolbox was employed for simulations, using an equivalent-source hologram and a uniform bowl source with parameters that best matched the measured free-field pressure distribution.<i>Main results.</i>The average absolute error in k-Wave simulations with sound speed and density derived from CT scans compared to measurements was 15% for the spatial-peak acoustic pressure amplitude, 2.7 mm for the position of the focus, and 35% for the focal volume. Optimised uniform bowl sources achieved calculation accuracy comparable to that of the hologram sources.<i>Significance.</i>This method is demonstrated as a suitable tool for prediction of focal position, size and overall distribution of transcranial ultrasound fields. The accuracy of the shape and position of the focal region demonstrate the suitability of the sound speed and density mapping used here. However, large errors in pressure amplitude and transmission loss in some individual cases show that alternative methods for mapping individual skull attenuation are needed and the possibility of considerable errors in pressure amplitude should be taken into account when planning focused ultrasound studies or interventions in the human brain, and appropriate safety margins should be used.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-12-19
DOI
https://doi.org/10.1088/1361-6560/ada19d
Citations
20
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
3.69

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparative study of experimental and simulated ultrasound beam propagation through cranial bones

Ian C. Simcock, Alisa A. Krokhmal, Bradley E. Treeby, Eleanor Martin
20 citations
Physics in Medicine and Biology
Ultrasound and Hyperthermia Applications
3.69
article

A comparative study of experimental and simulated ultrasound beam propagation through cranial bones

Ian C. Simcock, Alisa A. Krokhmal, Bradley E. Treeby, Eleanor Martin
article en
20 citations

Abstract

<i>Objective.</i>Transcranial ultrasound is used in a variety of treatments, including neuromodulation, opening the blood-brain barrier, and high intensity focused ultrasound therapies. To ensure safety and efficacy of these treatments, numerical simulations of the ultrasound field within the brain are used for treatment planning and evaluation. This study investigates the accuracy of numerical modelling of the propagation of focused ultrasound through cranial bones.<i>Approach.</i>Holograms of acoustic fields after propagation through four human skull specimens were measured for frequencies ranging from 270 kHz to 1 MHz, using both quasi-continuous and pulsed modes. The open-source k-Wave toolbox was employed for simulations, using an equivalent-source hologram and a uniform bowl source with parameters that best matched the measured free-field pressure distribution.<i>Main results.</i>The average absolute error in k-Wave simulations with sound speed and density derived from CT scans compared to measurements was 15% for the spatial-peak acoustic pressure amplitude, 2.7 mm for the position of the focus, and 35% for the focal volume. Optimised uniform bowl sources achieved calculation accuracy comparable to that of the hologram sources.<i>Significance.</i>This method is demonstrated as a suitable tool for prediction of focal position, size and overall distribution of transcranial ultrasound fields. The accuracy of the shape and position of the focal region demonstrate the suitability of the sound speed and density mapping used here. However, large errors in pressure amplitude and transmission loss in some individual cases show that alternative methods for mapping individual skull attenuation are needed and the possibility of considerable errors in pressure amplitude should be taken into account when planning focused ultrasound studies or interventions in the human brain, and appropriate safety margins should be used.

Physics in Medicine and BiologyVol. 70(2)
Great Ormond Street Hospital (GB), Great Ormond Street Hospital for Children NHS Foundation Trust (GB), Wellcome / EPSRC Centre for Interventional and Surgical Sciences (GB), Institute of Child Health (GR), University College London (GB)
UK Research and Innovation, National Institute for Health and Care Research, Wellcome / EPSRC Centre for Interventional and Surgical Sciences, Medical Research Council, Engineering and Physical Sciences Research Council
Good health and well-being
Openalex Percentile: Top 6%
Ultrasound and Hyperthermia Applications
3.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.