Rapid Detection of Feline Calicivirus Using Lateral Flow Dipsticks Based on CRISPR/Cas13a System

Feline calicivirus (FCV) is one of the most common viral pathogens in domestic cats worldwide, which mainly causes upper respiratory tract infections in felines and seriously threatens the health of felines. Consequently, it is crucial to establish a rapid detection method to efficiently take control and prevent the spread of FCV. To construct the Cas13a-RAA-LFD reaction system, this study specifically designed recombinase-aided amplification (RAA) primers added with a T7 promoter and CRISPR RNA (crRNA), which were both based on the FCV relatively conserved sequence. The Cas13a protein cleaved the reporting probes only when crRNA recognized the target sequence. The results could be directly observed by lateral flow dipsticks (LFDs). To evaluate this system, factors such as RAA amplification time, Cas13a protein concentration, crRNA concentration, and CRISPR reaction time were optimized. Then, a comparison of the coincidence rate for clinical samples between this method and the polymerase chain reaction (PCR) agarose electrophoresis method was performed to evaluate the reliability of the method. Eventually, the results indicated that the target gene could be effectively amplified by the Cas13a-RAA-LFD method, and the results could be visually observed by LFD. The method could detect FCV specifically, whilst having no cross-reaction with other common viruses which infect felines, such as feline parvovirus (FPV), feline coronavirus (FCoV) and feline herpesvirus (FHV). This method is extremely sensitive and has been validated to detect viral nucleic acids down to 10<sup>0</sup> copies/μL. The good reproducibility and stability of the method were also verified by this study. Testing of clinical samples proved that the coincidence rate of clinical detection reached 96.39%. In summary, this study established a simplistic, efficient, accurate, and visualized FCV detection method, which can be utilized for early prevention and control of FCV.

Authors

Institutions

Publication Details

Journal
Animals
Published
2024-12-18
DOI
https://doi.org/10.3390/ani14243663
Citations
5
Primary Topic
CRISPR and Genetic Engineering
Type
article
Field-Weighted Citation Impact
1.17

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Detection of Feline Calicivirus Using Lateral Flow Dipsticks Based on CRISPR/Cas13a System

Tie Zhang, Zichuang Zhang, Chengqi Zhang, Xue Bai et al.
5 citations
Animals
CRISPR and Genetic Engineering
1.17
article

Rapid Detection of Feline Calicivirus Using Lateral Flow Dipsticks Based on CRISPR/Cas13a System

Tie Zhang, Zichuang Zhang, Chengqi Zhang, Xue Bai, Jing Li
article en
5 citations

Abstract

Feline calicivirus (FCV) is one of the most common viral pathogens in domestic cats worldwide, which mainly causes upper respiratory tract infections in felines and seriously threatens the health of felines. Consequently, it is crucial to establish a rapid detection method to efficiently take control and prevent the spread of FCV. To construct the Cas13a-RAA-LFD reaction system, this study specifically designed recombinase-aided amplification (RAA) primers added with a T7 promoter and CRISPR RNA (crRNA), which were both based on the FCV relatively conserved sequence. The Cas13a protein cleaved the reporting probes only when crRNA recognized the target sequence. The results could be directly observed by lateral flow dipsticks (LFDs). To evaluate this system, factors such as RAA amplification time, Cas13a protein concentration, crRNA concentration, and CRISPR reaction time were optimized. Then, a comparison of the coincidence rate for clinical samples between this method and the polymerase chain reaction (PCR) agarose electrophoresis method was performed to evaluate the reliability of the method. Eventually, the results indicated that the target gene could be effectively amplified by the Cas13a-RAA-LFD method, and the results could be visually observed by LFD. The method could detect FCV specifically, whilst having no cross-reaction with other common viruses which infect felines, such as feline parvovirus (FPV), feline coronavirus (FCoV) and feline herpesvirus (FHV). This method is extremely sensitive and has been validated to detect viral nucleic acids down to 10<sup>0</sup> copies/μL. The good reproducibility and stability of the method were also verified by this study. Testing of clinical samples proved that the coincidence rate of clinical detection reached 96.39%. In summary, this study established a simplistic, efficient, accurate, and visualized FCV detection method, which can be utilized for early prevention and control of FCV.

AnimalsVol. 14(24)
Hebei Agricultural University (CN), Institute of Special Animal and Plant Sciences (CN)
People's Government of Jilin Province, Department of Science and Technology of Jilin Province, National Key Research and Development Program of China
Openalex Percentile: Top 21%
CRISPR and Genetic Engineering
1.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.