Development and clinical validation of photochemical biosensors for monitoring hemoglobin, blood lipids and uric acid in plateau areas

High-altitude regions are prone to plateau erythrocytosis due to unique geo-climatic conditions such as low oxygen, high altitude, and low temperatures, with significantly higher incidences of hyperlipidemia and hyperuricemia compared to lowland areas. However, the extreme environmental conditions at high altitudes and the elevated hematocrit levels in blood samples from these populations present significant challenges to the applicability of existing point-of-care testing (POCT) devices. This study describes the development, early clinical validation, and potential clinical impact of three portable, paper-based photochemical biosensing platforms specifically designed for use at high altitudes to monitor hemoglobin, lipids, and uric acid in blood samples. To systematically evaluate the performance of these sensors, 154 fresh venous blood samples from three distinct altitudes were tested and compared with a reference measurement system, alongside an extensive evaluation for the first time of the suitability of various commercially available POCT devices, including these platforms, for use in high-altitude environments. The results demonstrated that the accuracy and concordance between the developed platforms and the reference system were consistently above 95%. Additionally, concordance remained above 95% when the same samples were tested at varying altitudes (4500 m to 3650 m and 4800 m to 3650 m). All of this indicates that the sensing platform provides high accuracy and reliability for testing in high-altitude environments. It holds promise for broader application in the screening and management of chronic diseases in high-altitude and other extreme environments, and for advancing the use of bedside testing technology in resource-limited settings.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2024-12-20
DOI
https://doi.org/10.1039/d4ay01737d
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and clinical validation of photochemical biosensors for monitoring hemoglobin, blood lipids and uric acid in plateau areas

Li Shi, Jinhong Guo, Zhijuan Liu, Qiuping Li et al.
Analytical Methods
Analytical Chemistry and Sensors
article

Development and clinical validation of photochemical biosensors for monitoring hemoglobin, blood lipids and uric acid in plateau areas

Li Shi, Jinhong Guo, Zhijuan Liu, Qiuping Li, Xiaoyan Xiang, Jie Cheng, Bo Yu, Qiong Huang, Danzeng Quda, Gasong Zhuoga, Wei Dong Zhang
article en

Abstract

High-altitude regions are prone to plateau erythrocytosis due to unique geo-climatic conditions such as low oxygen, high altitude, and low temperatures, with significantly higher incidences of hyperlipidemia and hyperuricemia compared to lowland areas. However, the extreme environmental conditions at high altitudes and the elevated hematocrit levels in blood samples from these populations present significant challenges to the applicability of existing point-of-care testing (POCT) devices. This study describes the development, early clinical validation, and potential clinical impact of three portable, paper-based photochemical biosensing platforms specifically designed for use at high altitudes to monitor hemoglobin, lipids, and uric acid in blood samples. To systematically evaluate the performance of these sensors, 154 fresh venous blood samples from three distinct altitudes were tested and compared with a reference measurement system, alongside an extensive evaluation for the first time of the suitability of various commercially available POCT devices, including these platforms, for use in high-altitude environments. The results demonstrated that the accuracy and concordance between the developed platforms and the reference system were consistently above 95%. Additionally, concordance remained above 95% when the same samples were tested at varying altitudes (4500 m to 3650 m and 4800 m to 3650 m). All of this indicates that the sensing platform provides high accuracy and reliability for testing in high-altitude environments. It holds promise for broader application in the screening and management of chronic diseases in high-altitude and other extreme environments, and for advancing the use of bedside testing technology in resource-limited settings.

Analytical MethodsVol. 17(4)
Guilin Medical University (CN), Shanghai Jiao Tong University (CN), Runze (China) (CN), Tibet Autonomous Region People's Hospital (CN)
Climate action
Openalex Percentile: Top 75%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.