Thyroid and lens absorbed dose assessment during different interventional and surgical procedures: a multicentre study

A priori estimation of staff exposure during medical interventional procedures involving the use of ionising radiation is essential to carry out an adequate risk assessment and, therefore, to define the maximum workloads, to choose appropriate dosimeters and additional shielding. To date, research activity has been mainly focused on cardiac procedures, which involve high dose rates, and much attention is paid to the optimisation of radiation protection in this field. The purpose of this retrospective study was to evaluate the dose exposure of different healthcare professionals starting from the Dose Area Products (DAPs) recorded after various interventional (non-cardiac) and surgical procedures. A total of 374 operators, 2829 interventional procedures and 4463 surgical procedures were considered. Estimated thyroid/lens absorbed dose (median-75%) for surgeons/interventionists were as follows (ìSv/procedure). Interventional procedures: endoscopy (107–121)/(85–97) and urology (60–130)/(48–104); surgeries: vascular (68–73)/(55–60), general (28–35)/(22–28), orthopaedic (6–9)/(5–7). After grouping the data of all the procedures, the same estimations are reported for anesthesiologists (15–29)/(13–25), nurses (13–24)/(11–20) and radiographers (15–32)/(12–26).

Authors

Publication Details

Journal
Annals of the ICRP
Published
2024-12-01
DOI
https://doi.org/10.1177/01466453241283931an
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thyroid and lens absorbed dose assessment during different interventional and surgical procedures: a multicentre study

L.N. Mazzoni, Luca Bernardi, V. Favuzza, S. Pini et al.
Annals of the ICRP
Radiation Dose and Imaging
article

Thyroid and lens absorbed dose assessment during different interventional and surgical procedures: a multicentre study

L.N. Mazzoni, Luca Bernardi, V. Favuzza, S. Pini, L. Fedeli, David A. Fedele, S. Mazzocchi, A. Vaiano, M. Betti
article en

Abstract

A priori estimation of staff exposure during medical interventional procedures involving the use of ionising radiation is essential to carry out an adequate risk assessment and, therefore, to define the maximum workloads, to choose appropriate dosimeters and additional shielding. To date, research activity has been mainly focused on cardiac procedures, which involve high dose rates, and much attention is paid to the optimisation of radiation protection in this field. The purpose of this retrospective study was to evaluate the dose exposure of different healthcare professionals starting from the Dose Area Products (DAPs) recorded after various interventional (non-cardiac) and surgical procedures. A total of 374 operators, 2829 interventional procedures and 4463 surgical procedures were considered. Estimated thyroid/lens absorbed dose (median-75%) for surgeons/interventionists were as follows (ìSv/procedure). Interventional procedures: endoscopy (107–121)/(85–97) and urology (60–130)/(48–104); surgeries: vascular (68–73)/(55–60), general (28–35)/(22–28), orthopaedic (6–9)/(5–7). After grouping the data of all the procedures, the same estimations are reported for anesthesiologists (15–29)/(13–25), nurses (13–24)/(11–20) and radiographers (15–32)/(12–26).

Annals of the ICRPVol. 53(1_suppl)
Openalex Percentile: Top 60%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.