Modeling of heavy charged particle tracks overlap by pair of Al2O3:C, Mg dosimeters

Ion beam therapy (IBT) is the medical use of heavy charged particles to treat cancer due to their physical and biological properties, and damage the tumor at a given physical dose without causing damage to healthy tissues. The aim of this study was to investigate the ion track overlap (TO) from aluminium oxide doped with carbon and magnesium (Al 2 O 3 :C-Mg) dosimeters as a probability function. The dosimeters were exposed to proton 3 MeV u −1 and carbon 26 MeV u −1 heavy charged particle (HCP) beams-dosimeters in the interval of fluencies from 2.23 × 10 6 to 8.93 × 10 7 (ion cm −2 ). The TO occurs for fluencies higher than 10 6 cm 2 for all radiation types. A model for the TO process was developed, considering the dependence of the quantity of TO on the number of simulated tracks by a probability function, also the number of total induced tracks was determined. As the particle fluence increases, TO also increases, leading to increasing the number of track per spot. Therefore, the HCP fluence or dose at which the histogram starts to change may be an indication of onset of TO. It was observed that, TO starts from the fluence above 10 6 cm 2 , also the number of track per spot was increased with the increase of the fluence and the probability of getting one track per spot is approximately 100%. for the very low fluence.

Authors

Institutions

Publication Details

Journal
Annals of the ICRP
Published
2024-12-01
DOI
https://doi.org/10.1177/01466453241283931n
Primary Topic
Nuclear Materials and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling of heavy charged particle tracks overlap by pair of Al2O3:C, Mg dosimeters

S. Elshiekh, M.A.A. Kehail
Annals of the ICRP
Nuclear Materials and Properties
article

Modeling of heavy charged particle tracks overlap by pair of Al2O3:C, Mg dosimeters

S. Elshiekh, M.A.A. Kehail
article en

Abstract

Ion beam therapy (IBT) is the medical use of heavy charged particles to treat cancer due to their physical and biological properties, and damage the tumor at a given physical dose without causing damage to healthy tissues. The aim of this study was to investigate the ion track overlap (TO) from aluminium oxide doped with carbon and magnesium (Al 2 O 3 :C-Mg) dosimeters as a probability function. The dosimeters were exposed to proton 3 MeV u −1 and carbon 26 MeV u −1 heavy charged particle (HCP) beams-dosimeters in the interval of fluencies from 2.23 × 10 6 to 8.93 × 10 7 (ion cm −2 ). The TO occurs for fluencies higher than 10 6 cm 2 for all radiation types. A model for the TO process was developed, considering the dependence of the quantity of TO on the number of simulated tracks by a probability function, also the number of total induced tracks was determined. As the particle fluence increases, TO also increases, leading to increasing the number of track per spot. Therefore, the HCP fluence or dose at which the histogram starts to change may be an indication of onset of TO. It was observed that, TO starts from the fluence above 10 6 cm 2 , also the number of track per spot was increased with the increase of the fluence and the probability of getting one track per spot is approximately 100%. for the very low fluence.

Annals of the ICRPVol. 53(1_suppl)
University of Gezira (SD)
Openalex Percentile: Top 85%
Nuclear Materials and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.