Proof of Concept Study: Comparison of Semi-Automated RNA Isolation Methods from Archived Formalin-Fixed, Paraffin-Embedded Tissues with Clinical Routine RNA Isolation Methods

High-quality RNA is crucial in clinical diagnostics and precision medicine. Formalin-fixed and paraffin-embedded (FFPE) tissues pose a challenge due to nucleic acid fragmentation and crosslinking. In this pilot study, various commercially available techniques for extracting RNA from small FFPE samples were compared. We evaluated the KingFisher Duo automated system or the manual MagMAX FFPE DNA/RNA Ultra Kit as an RNA extraction method combined with either a xylene, d-limonene, or AutoLys M tubes deparaffinization method. Additionally, the automated Maxwell RSC RNA FFPE kit and the High Pure FFPET RNA Isolation Kit were examined using FFPE samples from inflammatory bowel disease (IBD) patients, as well as samples from ovarian, kidney, and breast cancer and the skin. The KingFisher Duo system gave a higher yield and more consistent RNA quantities, especially from small volumes of IBD samples, compared to manual extraction. The deparaffinization method also impacted results, with AutoLys M tubes proving effective in combination with the KingFisher Duo system. Conversely, the High Pure kit exhibited higher yields for larger FFPE samples. While RNA integrity is a critical factor, particularly for messenger RNA (mRNA) expression studies, its role is less prominent in microRNA (miRNA) analyses. Recognizing this, our study focused on RNA yield and purity (A260/A230) to evaluate RNA extraction methods for various sample types. These findings emphasize the importance of selecting appropriate RNA extraction methods based on sample characteristics and research goals, highlighting the performance of automated methods and the impact of deparaffinization choices. The findings contribute to refining RNA extraction for molecular biology analyses, suggesting avenues for further exploration, including cost-effectiveness under specific experimental conditions.

Authors

Institutions

Publication Details

Journal
Methods and Protocols
Published
2024-12-19
DOI
https://doi.org/10.3390/mps7060101
Primary Topic
Molecular Biology Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proof of Concept Study: Comparison of Semi-Automated RNA Isolation Methods from Archived Formalin-Fixed, Paraffin-Embedded Tissues with Clinical Routine RNA Isolation Methods

Claus Høgdall, Estrid Høgdall, Patrick H D Petersen, Lene Riis et al.
Methods and Protocols
Molecular Biology Techniques and Applications
article

Proof of Concept Study: Comparison of Semi-Automated RNA Isolation Methods from Archived Formalin-Fixed, Paraffin-Embedded Tissues with Clinical Routine RNA Isolation Methods

Claus Høgdall, Estrid Høgdall, Patrick H D Petersen, Lene Riis, Jaslin James
article en

Abstract

High-quality RNA is crucial in clinical diagnostics and precision medicine. Formalin-fixed and paraffin-embedded (FFPE) tissues pose a challenge due to nucleic acid fragmentation and crosslinking. In this pilot study, various commercially available techniques for extracting RNA from small FFPE samples were compared. We evaluated the KingFisher Duo automated system or the manual MagMAX FFPE DNA/RNA Ultra Kit as an RNA extraction method combined with either a xylene, d-limonene, or AutoLys M tubes deparaffinization method. Additionally, the automated Maxwell RSC RNA FFPE kit and the High Pure FFPET RNA Isolation Kit were examined using FFPE samples from inflammatory bowel disease (IBD) patients, as well as samples from ovarian, kidney, and breast cancer and the skin. The KingFisher Duo system gave a higher yield and more consistent RNA quantities, especially from small volumes of IBD samples, compared to manual extraction. The deparaffinization method also impacted results, with AutoLys M tubes proving effective in combination with the KingFisher Duo system. Conversely, the High Pure kit exhibited higher yields for larger FFPE samples. While RNA integrity is a critical factor, particularly for messenger RNA (mRNA) expression studies, its role is less prominent in microRNA (miRNA) analyses. Recognizing this, our study focused on RNA yield and purity (A260/A230) to evaluate RNA extraction methods for various sample types. These findings emphasize the importance of selecting appropriate RNA extraction methods based on sample characteristics and research goals, highlighting the performance of automated methods and the impact of deparaffinization choices. The findings contribute to refining RNA extraction for molecular biology analyses, suggesting avenues for further exploration, including cost-effectiveness under specific experimental conditions.

Methods and ProtocolsVol. 7(6)
University of Copenhagen (DK), Herlev Hospital (DK), Rigshospitalet (DK)
Herlev Hospital, Dansk Kræftforsknings Fond
Good health and well-being
Openalex Percentile: Top 79%
Molecular Biology Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.