Characterisation at Cryogenic Temperatures of an Attenuator for an Application of Astrophysical Instrumentation with MKIDs

The use of non-cryogenic certified commercial electronics for cryogenic applications may be attractive due to their cost and availability, but it also carries risks related to reliability, performance and thermal compatibility. The decision to use commercial components that are not certified for cryogenics instead of components specifically designed for such applications must be carefully weighed based on specific project needs and risk tolerances. This work presents the characterisation of an attenuator circuit at cryogenic temperatures used in a microwave kinetic inductance detector (MKID) readout system. In order to characterise the operation of the attenuator at cryogenic temperatures and because the circuit works at frequencies up to 40 GHz, a specific microwave PCB has been designed. The cooling system used consists of a cryostat, all the connectors, cables, a vacuum pump, a compressor, pressure and temperature sensors, a temperature control system and a cold head operating in a closed helium gas cycle according to the Gifford-McMahon principle. The circuit was tested and characterised at temperatures ranging from 296.5 K to 83.6 K.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-19
DOI
https://doi.org/10.3390/s24248129
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterisation at Cryogenic Temperatures of an Attenuator for an Application of Astrophysical Instrumentation with MKIDs

Hugo García‐Vázquez, J.J Diaz, E. Joven, Sergio Hernández et al.
Sensors
Superconducting and THz Device Technology
article

Characterisation at Cryogenic Temperatures of an Attenuator for an Application of Astrophysical Instrumentation with MKIDs

Hugo García‐Vázquez, J.J Diaz, E. Joven, Sergio Hernández, R. J. Hoyland, Luis Fernando Rodríguez-Ramos, Diego Portero-Rodríguez, José Luis Martínez-Rodríguez
article en

Abstract

The use of non-cryogenic certified commercial electronics for cryogenic applications may be attractive due to their cost and availability, but it also carries risks related to reliability, performance and thermal compatibility. The decision to use commercial components that are not certified for cryogenics instead of components specifically designed for such applications must be carefully weighed based on specific project needs and risk tolerances. This work presents the characterisation of an attenuator circuit at cryogenic temperatures used in a microwave kinetic inductance detector (MKID) readout system. In order to characterise the operation of the attenuator at cryogenic temperatures and because the circuit works at frequencies up to 40 GHz, a specific microwave PCB has been designed. The cooling system used consists of a cryostat, all the connectors, cables, a vacuum pump, a compressor, pressure and temperature sensors, a temperature control system and a cold head operating in a closed helium gas cycle according to the Gifford-McMahon principle. The circuit was tested and characterised at temperatures ranging from 296.5 K to 83.6 K.

SensorsVol. 24(24)
Universidad de La Laguna (ES), Instituto de Astrofísica de Canarias (ES)
Affordable and clean energy
Openalex Percentile: Top 83%
Superconducting and THz Device Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.