Influence of Current Density on the Morphology and Structure of Silver Nanoparticles on Anodized Titanium for Biomedical Implant Applications

This article focused on investigating the influence of current density on the morphology and structure of silver nanoparticles (n-Ag) electrodeposited on anodized titanium substrates (denoted as TiO 2 /Ti) on the surface. The TiO 2 /Ti substrate served as the cathodic electrode placed in an electrolyte solution containing ionic [Ag(NH 3 ) 2 ] + complex solution. The n-Ag/TiO 2 /Ti samples were synthesized at current densities ranging from 0.2 A/dm 2 to 0.5 A/dm 2 for 20 seconds at room temperature. The study performed morphological and surface composition analysis of n-Ag/TiO 2 /Ti using Field Emission Scanning Electron Microscopy (FESEM) and X-ray Diffraction (XRD) techniques. Additionally, the study assessed the electrochemical properties using the AutoLab system with Nova 2.1 software, based on Tafel curve measurements to compare the corrosion resistance of the samples before and after modification.

Authors

Institutions

Publication Details

Journal
Key engineering materials
Published
2024-12-19
DOI
https://doi.org/10.4028/p-pgn6al
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Current Density on the Morphology and Structure of Silver Nanoparticles on Anodized Titanium for Biomedical Implant Applications

Nguyễn Đức Hùng, Dang Minh Duc, Le Thi Lan, Le Van Toan et al.
1 citations
Key engineering materials
Bone Tissue Engineering Materials
0.18
article

Influence of Current Density on the Morphology and Structure of Silver Nanoparticles on Anodized Titanium for Biomedical Implant Applications

Nguyễn Đức Hùng, Dang Minh Duc, Le Thi Lan, Le Van Toan, Vuong Hung Pham
article en
1 citations

Abstract

This article focused on investigating the influence of current density on the morphology and structure of silver nanoparticles (n-Ag) electrodeposited on anodized titanium substrates (denoted as TiO 2 /Ti) on the surface. The TiO 2 /Ti substrate served as the cathodic electrode placed in an electrolyte solution containing ionic [Ag(NH 3 ) 2 ] + complex solution. The n-Ag/TiO 2 /Ti samples were synthesized at current densities ranging from 0.2 A/dm 2 to 0.5 A/dm 2 for 20 seconds at room temperature. The study performed morphological and surface composition analysis of n-Ag/TiO 2 /Ti using Field Emission Scanning Electron Microscopy (FESEM) and X-ray Diffraction (XRD) techniques. Additionally, the study assessed the electrochemical properties using the AutoLab system with Nova 2.1 software, based on Tafel curve measurements to compare the corrosion resistance of the samples before and after modification.

Key engineering materialsVol. 1002
Hanoi University of Science and Technology (VN)
Openalex Percentile: Top 49%
Bone Tissue Engineering Materials
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.