Molding Quality and Biological Evaluation of a Two-Stage Titanium Alloy Dental Implant Based on Combined 3D Printing and Subtracting Manufacturing

Metal 3D printing has been used in the manufacturing of dental implants. Its technical advantages include high material utilization and the capacity to form arbitrarily complex structures. However, 3D printing alone is insufficient for manufacturing two-stage titanium implants due to the limited precision in printing titanium alloy parts. In this study, 3D printing was employed to create the implant structure, subsequently complemented by mechanical processing to refine the implant abutment connection and neck. Additionally, the mechanical properties of 3D-printed titanium alloy implants were evaluated through tensile and dynamic fatigue testing. The MTT assay was employed to assess the cytotoxicity of 3D-printed titanium alloy dental implants. The impact of bone union and osteogenesis from 3D-printed titanium alloy dental implants was investigated through in vivo experimentation. The results demonstrated that combining 3D printing with subsequent machining constitutes a viable method for the manufacture of two-stage titanium dental implants. Test results for mechanical properties indicated that heat-treated 3D-printed titanium alloy dental implants possess significant tensile strength and fatigue resistance and are capable of withstanding the robust chewing forces in the oral cavity. In vitro findings revealed that sandblasted and acid-etched 3D-printed titanium alloy exhibited negligible cytotoxicity, with osteoblast differentiation of hMSCs being more pronounced compared with the control group. In vivo studies indicated that no significant differences were observed in bone volume fraction, bone-implant contact rate, and unscrewing torque between 3D-printed titanium alloy dental implants and commercial SLA surface implants at both 1 and 3 months postimplantation.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2024-12-19
DOI
https://doi.org/10.1021/acsomega.4c09131
Citations
3
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Molding Quality and Biological Evaluation of a Two-Stage Titanium Alloy Dental Implant Based on Combined 3D Printing and Subtracting Manufacturing

Dehua Li, Shitou Huang, Hongbo Wei, Yi Liu
3 citations
ACS Omega
Bone Tissue Engineering Materials
0.55
article

Molding Quality and Biological Evaluation of a Two-Stage Titanium Alloy Dental Implant Based on Combined 3D Printing and Subtracting Manufacturing

Dehua Li, Shitou Huang, Hongbo Wei, Yi Liu
article en
3 citations

Abstract

Metal 3D printing has been used in the manufacturing of dental implants. Its technical advantages include high material utilization and the capacity to form arbitrarily complex structures. However, 3D printing alone is insufficient for manufacturing two-stage titanium implants due to the limited precision in printing titanium alloy parts. In this study, 3D printing was employed to create the implant structure, subsequently complemented by mechanical processing to refine the implant abutment connection and neck. Additionally, the mechanical properties of 3D-printed titanium alloy implants were evaluated through tensile and dynamic fatigue testing. The MTT assay was employed to assess the cytotoxicity of 3D-printed titanium alloy dental implants. The impact of bone union and osteogenesis from 3D-printed titanium alloy dental implants was investigated through in vivo experimentation. The results demonstrated that combining 3D printing with subsequent machining constitutes a viable method for the manufacture of two-stage titanium dental implants. Test results for mechanical properties indicated that heat-treated 3D-printed titanium alloy dental implants possess significant tensile strength and fatigue resistance and are capable of withstanding the robust chewing forces in the oral cavity. In vitro findings revealed that sandblasted and acid-etched 3D-printed titanium alloy exhibited negligible cytotoxicity, with osteoblast differentiation of hMSCs being more pronounced compared with the control group. In vivo studies indicated that no significant differences were observed in bone volume fraction, bone-implant contact rate, and unscrewing torque between 3D-printed titanium alloy dental implants and commercial SLA surface implants at both 1 and 3 months postimplantation.

ACS OmegaVol. 9(52)
National Clinical Research (US), Air Force Medical University (CN)
Key Research and Development Projects of Shaanxi Province
Industry, innovation and infrastructure
Openalex Percentile: Top 36%
Bone Tissue Engineering Materials
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.