Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time: An In Vitro Study
The study confirms that the calibrated Stratos 300 semi-adjustable articulators provide consistent and accurate occlusal measurements over time, regardless of their usage over time. How to cite this article: Almalki A, Kutkut N, Althubaitiy R, <i>et al.</i> Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time: An <i>In Vitro</i> Study. J Contemp Dent Pract 2024;25(9):869-872.
Authors
- Ali Robaian (ORCID: https://orcid.org/0000-0002-1388-0890)
- Evanthia Anadioti
- Ramzi O. Althubaitiy (ORCID: https://orcid.org/0000-0002-5864-6555)
- Noor Kutkut
- Abdulrahman Almalki (ORCID: https://orcid.org/0000-0002-4654-7541)
- Khaled Alzaharni
Institutions
- Prince Sattam Bin Abdulaziz University (SA)
- University of Pennsylvania (US)
Publication Details
- Journal
- The Journal of Contemporary Dental Practice
- Published
- 2024-12-19
- DOI
- https://doi.org/10.5005/jp-journals-10024-3752
- Primary Topic
- Ergonomics and Musculoskeletal Disorders
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- University of Pennsylvania