Effective Ammonia Removal from Hospital Wastewater by Using a Combination of Filtrations and Bio-Adsorbent from Tea Waste

Hospital wastewater contains a high concentration of ammonia that exceed the predetermined quality standards and can cause pollution to the environment. Therefore, the treatment of hospital wastewater is required prior to being released to the environment. Effective ammonia removal process has been developed by using a combination of sponge filtration pretreatment, followed by adsorption using activated carbon from waste of tea leaves, and nanofiltration using ceramic membrane as the final process. Experiment results show the highest effectiveness of ammonia removal of 70% by using filtration only. Effectiveness is increases up to 95% by a combination of filtration and adsorption. A maximum effectiveness of 100% is achieved when using a combination of filtration, adsorption, and nanofiltration. This combination produces an optimal condition for the ammonia removal by using 3 L/min flowrate, adsorbent mass 140 g, and operating time 15 minutes at which the ammonia concentration is 0.08 mg/L. This concentration is below the standard of allowable ammonia concentration of 0.1 mg/L.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Environmental Management and Sustainability
Published
2024-12-19
DOI
https://doi.org/10.26554/ijems.2024.8.4.145-153
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effective Ammonia Removal from Hospital Wastewater by Using a Combination of Filtrations and Bio-Adsorbent from Tea Waste

Elda Melwita, Subriyer Nasir, Shinta Ariani
Indonesian Journal of Environmental Management and Sustainability
Water Quality Monitoring Technologies
article

Effective Ammonia Removal from Hospital Wastewater by Using a Combination of Filtrations and Bio-Adsorbent from Tea Waste

Elda Melwita, Subriyer Nasir, Shinta Ariani
article en

Abstract

Hospital wastewater contains a high concentration of ammonia that exceed the predetermined quality standards and can cause pollution to the environment. Therefore, the treatment of hospital wastewater is required prior to being released to the environment. Effective ammonia removal process has been developed by using a combination of sponge filtration pretreatment, followed by adsorption using activated carbon from waste of tea leaves, and nanofiltration using ceramic membrane as the final process. Experiment results show the highest effectiveness of ammonia removal of 70% by using filtration only. Effectiveness is increases up to 95% by a combination of filtration and adsorption. A maximum effectiveness of 100% is achieved when using a combination of filtration, adsorption, and nanofiltration. This combination produces an optimal condition for the ammonia removal by using 3 L/min flowrate, adsorbent mass 140 g, and operating time 15 minutes at which the ammonia concentration is 0.08 mg/L. This concentration is below the standard of allowable ammonia concentration of 0.1 mg/L.

Indonesian Journal of Environmental Management and SustainabilityVol. 8(4)
Sriwijaya University (ID)
Universitas Sriwijaya
Clean water and sanitation
Openalex Percentile: Top 77%
Water Quality Monitoring Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.