Cherenkov real-time monitor for proton flash therapy

Abstract Flash therapy with ultra-high dose rate beams opens up the possibility of significantly reducing radiation damage to normal tissues. But that type of radiotherapy requires the development of new methods for dosimetry and monitoring of beams, since many conventional detectors are not fully suitable for these purposes. In this work, the characteristics of a new proton beam monitor that detects Cherenkov radiation from secondary delta electrons were studied in flash mode of irradiation. This monitor is applicable for proton beams of any intensity, very transparent for fast protons, and can provide real-time control of the absorbed dose and beam position. To record Cherenkov radiation, generated in a thin glass radiator located in the beam in front of the target, we used single-channel and multichannel photomultipliers. Proton beams with an energy of 160 MeV and a current of 1 mA were studied. The readings of a Cherenkov monitor, EBT-XD films, and a beam current transformer were compared and consistency of these detectors was found. The linearity of the Cherenkov monitor readings vs dose is very high ( R 2 = 0.9995). This monitor can be used for real-time control of the absorbed dose and of the beam position in flash therapy for any intensity of proton beams.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-12-01
DOI
https://doi.org/10.1088/1748-0221/19/12/p12025
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cherenkov real-time monitor for proton flash therapy

Yu. K. Gavrilov, С. В. Акулиничев, R. Djilkibaev
Journal of Instrumentation
Radiation Therapy and Dosimetry
article

Cherenkov real-time monitor for proton flash therapy

Yu. K. Gavrilov, С. В. Акулиничев, R. Djilkibaev
article en

Abstract

Abstract Flash therapy with ultra-high dose rate beams opens up the possibility of significantly reducing radiation damage to normal tissues. But that type of radiotherapy requires the development of new methods for dosimetry and monitoring of beams, since many conventional detectors are not fully suitable for these purposes. In this work, the characteristics of a new proton beam monitor that detects Cherenkov radiation from secondary delta electrons were studied in flash mode of irradiation. This monitor is applicable for proton beams of any intensity, very transparent for fast protons, and can provide real-time control of the absorbed dose and beam position. To record Cherenkov radiation, generated in a thin glass radiator located in the beam in front of the target, we used single-channel and multichannel photomultipliers. Proton beams with an energy of 160 MeV and a current of 1 mA were studied. The readings of a Cherenkov monitor, EBT-XD films, and a beam current transformer were compared and consistency of these detectors was found. The linearity of the Cherenkov monitor readings vs dose is very high ( R 2 = 0.9995). This monitor can be used for real-time control of the absorbed dose and of the beam position in flash therapy for any intensity of proton beams.

Journal of InstrumentationVol. 19(12)
Institute for Nuclear Research (RU), Institute of Spectroscopy (RU), Russian Scientific Center of Surgery (RU)
Openalex Percentile: Top 57%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.