Evidence of charge multiplication in thin 25 μm × 25 μm pitch 3D silicon sensors

Abstract Characterization measurements of 25 μm × 25 μm pitch 3D silicon sensors are performed, for devices with active thickness of 150 μm. Evidence of charge multiplication caused by impact ionization below the breakdown voltage is observed in sensors operated at -45 ∘ C. Small-pitch 3D silicon sensors have potential as high precision 4D tracking detectors that are also able to withstand radiation fluences beyond 10 16 n eq /cm 2 . This is applicable for use at future facilities such as the High-Luminosity Large Hadron Collider and the Future Circular Collider. Characteristics of these devices are compared to those of similar sensors of pitch 50 μm × 50 μm, showing comparable charge collection at low voltage, and acceptable leakage current, depletion voltage, breakdown voltage, and capacitance despite the extremely small cell size. The unirradiated 25 μm × 25 μm sensors exhibit charge multiplication above about 90 V reverse bias, while, as predicted, no multiplication is observed in the 50 μm × 50 μm sensors below their breakdown voltage. The maximum gain observed below breakdown is 1.33.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-12-01
DOI
https://doi.org/10.1088/1748-0221/19/12/p12024
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evidence of charge multiplication in thin 25 μm × 25 μm pitch 3D silicon sensors

G.‐F. Dalla Betta, Marco Povoli, S. Seidel, A. D. Gentry et al.
Journal of Instrumentation
Particle Detector Development and Performance
article

Evidence of charge multiplication in thin 25 μm × 25 μm pitch 3D silicon sensors

G.‐F. Dalla Betta, Marco Povoli, S. Seidel, A. D. Gentry, Jiahe Si, M. Boscardin, M. R. Hoeferkamp
article en

Abstract

Abstract Characterization measurements of 25 μm × 25 μm pitch 3D silicon sensors are performed, for devices with active thickness of 150 μm. Evidence of charge multiplication caused by impact ionization below the breakdown voltage is observed in sensors operated at -45 ∘ C. Small-pitch 3D silicon sensors have potential as high precision 4D tracking detectors that are also able to withstand radiation fluences beyond 10 16 n eq /cm 2 . This is applicable for use at future facilities such as the High-Luminosity Large Hadron Collider and the Future Circular Collider. Characteristics of these devices are compared to those of similar sensors of pitch 50 μm × 50 μm, showing comparable charge collection at low voltage, and acceptable leakage current, depletion voltage, breakdown voltage, and capacitance despite the extremely small cell size. The unirradiated 25 μm × 25 μm sensors exhibit charge multiplication above about 90 V reverse bias, while, as predicted, no multiplication is observed in the 50 μm × 50 μm sensors below their breakdown voltage. The maximum gain observed below breakdown is 1.33.

Journal of InstrumentationVol. 19(12)
University of New Mexico (US), SINTEF (NO), University of Trento (IT), Fondazione Bruno Kessler (IT), Istituto Nazionale di Fisica Nucleare, Trento Institute for Fundamental Physics And Applications (IT)
U.S. Department of Energy, National Aeronautics and Space Administration, New Mexico State University, Nuclear Safety and Security Commission, Goddard Space Flight Center, Nuclear Physics
Openalex Percentile: Top 93%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.