Experimental Study Modeling of The Effect of ESDD and NSDD on 150 kV Insulator

Abstract This study investigates the impact of equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) on the flashover voltage of 150 kV transmission line insulators. The high flashover rates on the Koto Panjang-Payakumbuh transmission line in Indonesia, particularly in hilly regions, indicate that contaminants significantly affect the insulator’s performance. The research utilizes the Anderson method and experimental data to analyze flashover voltage variations due to different contamination levels. Results show that the highest flashover voltage was observed at NSDD of 0.8401 mg/cm 2 with values of 395.44 kV (Anderson) and 346 kV (experiment), and the lowest at NSDD of 1.0151 mg/cm 2 with values of 394.40 kV (Anderson) and 341 kV (experiment). For ESDD, the highest voltage was at 160.8 mg/cm 2 with 395.44 kV (Anderson) and 341 kV (experiment), and the lowest at 258.6 mg/cm 2 with 394.40 kV (Anderson) and 341 kV (experiment). The strong correlation between flashover voltage and contaminant levels emphasizes the need for effective monitoring and control of contamination on insulators to improve reliability in power transmission systems.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-12-01
DOI
https://doi.org/10.1088/1742-6596/2923/1/012012
Citations
1
Primary Topic
Electrostatic Discharge in Electronics
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study Modeling of The Effect of ESDD and NSDD on 150 kV Insulator

Hamdi Azhar, Andi Syofian, Zuriman Anthony, Zulkarnaini et al.
1 citations
Journal of Physics Conference Series
Electrostatic Discharge in Electronics
0.21
article

Experimental Study Modeling of The Effect of ESDD and NSDD on 150 kV Insulator

Hamdi Azhar, Andi Syofian, Zuriman Anthony, Zulkarnaini, Yusreni Warmi, Sitti Amalia, Antonov Antonov
article en
1 citations

Abstract

Abstract This study investigates the impact of equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) on the flashover voltage of 150 kV transmission line insulators. The high flashover rates on the Koto Panjang-Payakumbuh transmission line in Indonesia, particularly in hilly regions, indicate that contaminants significantly affect the insulator’s performance. The research utilizes the Anderson method and experimental data to analyze flashover voltage variations due to different contamination levels. Results show that the highest flashover voltage was observed at NSDD of 0.8401 mg/cm 2 with values of 395.44 kV (Anderson) and 346 kV (experiment), and the lowest at NSDD of 1.0151 mg/cm 2 with values of 394.40 kV (Anderson) and 341 kV (experiment). For ESDD, the highest voltage was at 160.8 mg/cm 2 with 395.44 kV (Anderson) and 341 kV (experiment), and the lowest at 258.6 mg/cm 2 with 394.40 kV (Anderson) and 341 kV (experiment). The strong correlation between flashover voltage and contaminant levels emphasizes the need for effective monitoring and control of contamination on insulators to improve reliability in power transmission systems.

Journal of Physics Conference SeriesVol. 2923(1)
Institut Teknologi Padang (ID)
Openalex Percentile: Top 45%
Electrostatic Discharge in Electronics
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.