Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise

The gold standard to assess the aerobic capacity in physically active subjects and athletes is the maximal oxygen consumption test (VO2-max), which involves analysis of exhaled-gases and cardiorespiratory variables obtained via the breath-by-breath method in an ergospirometer during an incremental exercise. However, this method cannot elucidate metabolic changes at the muscular level. Near-infrared spectroscopy (NIRS) has emerged as a valuable technology to evaluate local oxygen levels (Tissular Saturation Index, TSI) by quantifying the concentrations of oxygenated (O2-Hb) and deoxygenated (H-Hb) hemoglobin in the microvasculature of tissues. NIRS applications extend to respiratory and locomotor muscles, assessing metabolic changes associated with the cost of breathing (COB) and peripheral workload, respectively. Additionally, cerebral regions, such as the prefrontal cortex, have been explored with NIRS technology to assess physiological changes related to cognitive demand associated with planning or ideation of motor tasks linked to sports performance. Thus, by analyzing exercise-induced changes (D) in O2-Hb, H-Hb, and TSI, it is possible to identify central and peripheral exercise limitations, particularly when endurance training is the main component of physical fitness (e.g., running, cycling, triathlon, etc.). Addressing these factors is paramount for coaches and exercise physiologists to optimize athletic performance, incorporating training strategies focused on the primary exercise-limiting factors. This study outlines a protocol for utilizing wearables devices equipped with NIRS technology to analyze exercise changes in TSI, O2-Hb, and H-Hb, alongside cardiorespiratory variables typically registered in athletes during VO2-max tests. This approach offers a comprehensive method for identifying the primary systems involved in stopping exercise progression and sports performance improvement.

Authors

Institutions

Publication Details

Journal
Journal of Visualized Experiments
Published
2024-12-19
DOI
https://doi.org/10.3791/67609
Citations
2
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise

Matías Carreño-Román, Maximiliano Espinosa‐Ramírez, Raúl Caulier‐Cisterna, Daniel Ramos‐López et al.
2 citations
Journal of Visualized Experiments
Infrared Thermography in Medicine
0.81
article

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise

Matías Carreño-Román, Maximiliano Espinosa‐Ramírez, Raúl Caulier‐Cisterna, Daniel Ramos‐López, Felipe Contreras–Briceño, Benjamín Rapaport
article en
2 citations

Abstract

The gold standard to assess the aerobic capacity in physically active subjects and athletes is the maximal oxygen consumption test (VO2-max), which involves analysis of exhaled-gases and cardiorespiratory variables obtained via the breath-by-breath method in an ergospirometer during an incremental exercise. However, this method cannot elucidate metabolic changes at the muscular level. Near-infrared spectroscopy (NIRS) has emerged as a valuable technology to evaluate local oxygen levels (Tissular Saturation Index, TSI) by quantifying the concentrations of oxygenated (O2-Hb) and deoxygenated (H-Hb) hemoglobin in the microvasculature of tissues. NIRS applications extend to respiratory and locomotor muscles, assessing metabolic changes associated with the cost of breathing (COB) and peripheral workload, respectively. Additionally, cerebral regions, such as the prefrontal cortex, have been explored with NIRS technology to assess physiological changes related to cognitive demand associated with planning or ideation of motor tasks linked to sports performance. Thus, by analyzing exercise-induced changes (D) in O2-Hb, H-Hb, and TSI, it is possible to identify central and peripheral exercise limitations, particularly when endurance training is the main component of physical fitness (e.g., running, cycling, triathlon, etc.). Addressing these factors is paramount for coaches and exercise physiologists to optimize athletic performance, incorporating training strategies focused on the primary exercise-limiting factors. This study outlines a protocol for utilizing wearables devices equipped with NIRS technology to analyze exercise changes in TSI, O2-Hb, and H-Hb, alongside cardiorespiratory variables typically registered in athletes during VO2-max tests. This approach offers a comprehensive method for identifying the primary systems involved in stopping exercise progression and sports performance improvement.

Journal of Visualized Experiments(214)
Pontificia Universidad Católica de Chile (CL), Metropolitan University of Technology (CL)
Openalex Percentile: Top 24%
Infrared Thermography in Medicine
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.