The soft-membrane surface forces apparatus

Compliant walls are widespread in biological and engineering systems. Because of their singular nature, adapted tools are required to accurately study their rheological properties and the consequences of the latter within a given mechanical setting. Because of their slender nature, membranes can be considered as prototypical examples of highly compliant boundaries. In this study, we describe a modified surface forces apparatus developed to measure the forces acting on a compliant membrane by measuring its deformation field. We discuss how such a device can be used to characterize the rheology of suspended membranes and accurately measure the electrostatic interactions between a polarized membrane and a spherical electrode, without the need of an external measurement spring.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-04-01
DOI
https://doi.org/10.1063/5.0253527
Primary Topic
Force Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The soft-membrane surface forces apparatus

Lionel Buisson, Yacine Amarouchène, Carlos Drummond, Thomas Salez et al.
Review of Scientific Instruments
Force Microscopy Techniques and Applications
article

The soft-membrane surface forces apparatus

Lionel Buisson, Yacine Amarouchène, Carlos Drummond, Thomas Salez, Aditya Jha, Ilyes Jalisse, Frédéric Nallet
article en

Abstract

Compliant walls are widespread in biological and engineering systems. Because of their singular nature, adapted tools are required to accurately study their rheological properties and the consequences of the latter within a given mechanical setting. Because of their slender nature, membranes can be considered as prototypical examples of highly compliant boundaries. In this study, we describe a modified surface forces apparatus developed to measure the forces acting on a compliant membrane by measuring its deformation field. We discuss how such a device can be used to characterize the rheology of suspended membranes and accurately measure the electrostatic interactions between a polarized membrane and a spherical electrode, without the need of an external measurement spring.

Review of Scientific InstrumentsVol. 96(4)
Centre National de la Recherche Scientifique (FR), Université de Bordeaux (FR), Center for Research in Psychopathology and Clinical Psychology (FR), Centre de recherche Paul Pascal (FR), Laboratoire Ondes et Matière d'Aquitaine (FR)
European Commission, Agence Nationale de la Recherche, Centre National de la Recherche Scientifique, Hokkaido University, Université de Bordeaux, HORIZON EUROPE European Research Council
Openalex Percentile: Top 100%
Force Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The soft-membrane surface forces apparatus — Lionel Buisson, Yacine Amarouchène, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS