Volumetric imaging of trabecular meshwork dynamic motion using 600 kHz swept source optical coherence tomography

The motion of the trabecular meshwork (TM) facilitates the aqueous drainage from the anterior chamber to the venous system, thereby maintaining normal intraocular pressure. As such, characterizing the TM motion is valuable for assessing the functionality of the aqueous outflow system, as demonstrated by previous phase-sensitive optical coherence tomography (OCT) studies. Current methods typically acquire motion from a single cross-sectional plane along the circumference of the anterior chamber. While effective, the lateral scan pattern only intersects one spatial location on the TM at a time, significantly limiting examination throughput. In this study, we introduce the first volumetric imaging approach for assessing TM motion. Rather than monitoring a single cross-sectional plane, our method employs repeated volumetric scans, allowing for simultaneous observation of a continuous TM band spanning two millimeters. We also show that the field of view could be further expanded by stitching multiple scans. To ensure robust data processing, we developed a customized volume registration algorithm to correct motion artifacts and an automated segmentation algorithm to identify the TM boundary based on the correlation of OCT phase dynamics with heartbeats. Imaging results from a healthy subject confirmed the feasibility of our approach, revealing considerable variation in TM motions at different spatial locations through the stitching process. This proposed methodology offers unprecedented capabilities and examination throughput in the biomechanical imaging of the TM, providing significant scientific insights and diagnostic value for identifying abnormalities in aqueous outflow.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-12-18
DOI
https://doi.org/10.1364/boe.544521
Citations
5
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Volumetric imaging of trabecular meshwork dynamic motion using 600 kHz swept source optical coherence tomography

Yaping Shi, Murray Johnstone, Zhaoyu Gong, Ruikang K. Wang et al.
5 citations
Biomedical Optics Express
Optical Coherence Tomography Applications
0.92
article

Volumetric imaging of trabecular meshwork dynamic motion using 600 kHz swept source optical coherence tomography

Yaping Shi, Murray Johnstone, Zhaoyu Gong, Ruikang K. Wang, Jianjun Liu, Yi Zhang
article en
5 citations

Abstract

The motion of the trabecular meshwork (TM) facilitates the aqueous drainage from the anterior chamber to the venous system, thereby maintaining normal intraocular pressure. As such, characterizing the TM motion is valuable for assessing the functionality of the aqueous outflow system, as demonstrated by previous phase-sensitive optical coherence tomography (OCT) studies. Current methods typically acquire motion from a single cross-sectional plane along the circumference of the anterior chamber. While effective, the lateral scan pattern only intersects one spatial location on the TM at a time, significantly limiting examination throughput. In this study, we introduce the first volumetric imaging approach for assessing TM motion. Rather than monitoring a single cross-sectional plane, our method employs repeated volumetric scans, allowing for simultaneous observation of a continuous TM band spanning two millimeters. We also show that the field of view could be further expanded by stitching multiple scans. To ensure robust data processing, we developed a customized volume registration algorithm to correct motion artifacts and an automated segmentation algorithm to identify the TM boundary based on the correlation of OCT phase dynamics with heartbeats. Imaging results from a healthy subject confirmed the feasibility of our approach, revealing considerable variation in TM motions at different spatial locations through the stitching process. This proposed methodology offers unprecedented capabilities and examination throughput in the biomechanical imaging of the TM, providing significant scientific insights and diagnostic value for identifying abnormalities in aqueous outflow.

Biomedical Optics ExpressVol. 16(1)
University of Washington (US)
Research to Prevent Blindness
Affordable and clean energy
Openalex Percentile: Top 27%
Optical Coherence Tomography Applications
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.