An integrated magnetoimpedance biosensor microfluidic magnetic platform for the evaluation of the cardiac marker cTnI

An integrated magnetoimpedance (MI) biosensor microfluidic magnetic platform was proposed for the evaluation of the cardiac marker, cardiac troponin I (cTnI). This bioanalyte evaluation platform mainly comprised three external permanent magnets (PMs), one MI element, two peelable SiO<sub>2</sub> film units and a microfluidic chip (MFC). The MI element was made of micro-electro-mechanical system (MEMS)-based multilayered [Ti (6 nm)/FeNi (100 nm)]<sub>5</sub>/Cu (400 nm)/[Ti (6 nm)/FeNi (100 nm)]<sub>5</sub> thin films and designed as meander structures with closed magnetic flux. The MFC was fabricated using 3D printing and inverted molding techniques, designed with a solution by mixing the reaction region, magnetic separation region and detection region. Peelable SiO<sub>2</sub> film units with the same size as the MI sensing element were used as the immunoreactivity interface of the bioanalytes. Two large PMs were placed directly below the MI sensing unit to provide a bias magnetic field, and the smaller PM was embedded in MCF for magnetic separation function. Different concentrations of the biological target (cTnI antigen)-, PBS buffer-, and Dynabeads-labeled polyclonal cTnI antibody solution were injected sequentially into the MCF. After immunoreactivity and magnetic separation, a classical sandwich immunoreaction process occurred on the surface of the monoclonal antibody-modified SiO<sub>2</sub> film <i>via</i> self-assembling process in the reaction region of the MFC. The fundamental principle for evaluation of cTnI was based on variations of the MI signal under different concentrations of the biological target coupled with different numbers of Dynabeads. It was demonstrated that the mentioned MI-based magnetic platform could perform quantitative detection analyses over a range of cTnI concentrations (lowest concentration = 0.1 ng mL<sup>-1</sup> and highest concentration = 100 ng mL<sup>-1</sup>). The proposed MI-based magnetic platform provides a sensitive, reliable, stable and reusable bioanalytical platform, and it has potential in future biomedical applications.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2024-12-18
DOI
https://doi.org/10.1039/d4ay02021a
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An integrated magnetoimpedance biosensor microfluidic magnetic platform for the evaluation of the cardiac marker cTnI

Jiabao Huang, Mengjiao Zhu, Yang Zhen, Jingyuan Chen et al.
Analytical Methods
Characterization and Applications of Magnetic Nanoparticles
article

An integrated magnetoimpedance biosensor microfluidic magnetic platform for the evaluation of the cardiac marker cTnI

Jiabao Huang, Mengjiao Zhu, Yang Zhen, Jingyuan Chen, Yuanwei Shen, Xuecheng Sun, Danqing Li, Mengyu Liu, J. K. Liang, Chong Lei
article en

Abstract

An integrated magnetoimpedance (MI) biosensor microfluidic magnetic platform was proposed for the evaluation of the cardiac marker, cardiac troponin I (cTnI). This bioanalyte evaluation platform mainly comprised three external permanent magnets (PMs), one MI element, two peelable SiO<sub>2</sub> film units and a microfluidic chip (MFC). The MI element was made of micro-electro-mechanical system (MEMS)-based multilayered [Ti (6 nm)/FeNi (100 nm)]<sub>5</sub>/Cu (400 nm)/[Ti (6 nm)/FeNi (100 nm)]<sub>5</sub> thin films and designed as meander structures with closed magnetic flux. The MFC was fabricated using 3D printing and inverted molding techniques, designed with a solution by mixing the reaction region, magnetic separation region and detection region. Peelable SiO<sub>2</sub> film units with the same size as the MI sensing element were used as the immunoreactivity interface of the bioanalytes. Two large PMs were placed directly below the MI sensing unit to provide a bias magnetic field, and the smaller PM was embedded in MCF for magnetic separation function. Different concentrations of the biological target (cTnI antigen)-, PBS buffer-, and Dynabeads-labeled polyclonal cTnI antibody solution were injected sequentially into the MCF. After immunoreactivity and magnetic separation, a classical sandwich immunoreaction process occurred on the surface of the monoclonal antibody-modified SiO<sub>2</sub> film <i>via</i> self-assembling process in the reaction region of the MFC. The fundamental principle for evaluation of cTnI was based on variations of the MI signal under different concentrations of the biological target coupled with different numbers of Dynabeads. It was demonstrated that the mentioned MI-based magnetic platform could perform quantitative detection analyses over a range of cTnI concentrations (lowest concentration = 0.1 ng mL<sup>-1</sup> and highest concentration = 100 ng mL<sup>-1</sup>). The proposed MI-based magnetic platform provides a sensitive, reliable, stable and reusable bioanalytical platform, and it has potential in future biomedical applications.

Analytical MethodsVol. 17(5)
Shanghai University (CN), Guiyang Medical University (CN), National University of Singapore (SG), Shanghai Jiao Tong University (CN), Guangxi Normal University (CN), Affiliated Hospital of Guizhou Medical University (CN)
National Natural Science Foundation of China, China Scholarship Council, Natural Science Foundation of Shandong Province, Guangxi Normal University, Scientific Research and Technology Development Program of Guangxi, Education Department of Guangxi Zhuang Autonomous Region, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 78%
Characterization and Applications of Magnetic Nanoparticles
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.