In vitro biostability testing of stent cover materials

Abstract Cast polyurethane films made of an aliphatic polycarbonate-based thermoplastic polyurethane (Carbothane PC) and poly(ether urethane) (Pellethane) were manufactured and their biostability under a static strain rate was investigated in vitro in comparison to unloaded samples. The PU films were stretched to an elongation of 300% and exposed to hydrogen peroxide/cobalt chloride (H2O2/CoCl2) solution for specific periods of time (up to 63 days). Unstrained PU samples were treated in the same way for comparison. The samples were observed for surface degradation via scanning electron microscopy and the bulk erosion by measuring the weight difference. The surface roughness greatly increased in strained Pellethane with scanning electron microscopy (SEM) evidence of deep cracks and holes or ragged and stretched fractures perpendicular to the direction of stress. Carbothane showed a lower degradation compared with Pellethane under mechanical constraint.

Authors

Institutions

Publication Details

Journal
Current Directions in Biomedical Engineering
Published
2024-12-01
DOI
https://doi.org/10.1515/cdbme-2024-2095
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vitro biostability testing of stent cover materials

Stefan Siewert, Sebastian Kaule, Daniela Koper, Thomas Reske et al.
3 links
Current Directions in Biomedical Engineering
Coronary Interventions and Diagnostics
article

In vitro biostability testing of stent cover materials

Stefan Siewert, Sebastian Kaule, Daniela Koper, Thomas Reske, Klaus‐Peter Schmitz
article en

Abstract

Abstract Cast polyurethane films made of an aliphatic polycarbonate-based thermoplastic polyurethane (Carbothane PC) and poly(ether urethane) (Pellethane) were manufactured and their biostability under a static strain rate was investigated in vitro in comparison to unloaded samples. The PU films were stretched to an elongation of 300% and exposed to hydrogen peroxide/cobalt chloride (H2O2/CoCl2) solution for specific periods of time (up to 63 days). Unstrained PU samples were treated in the same way for comparison. The samples were observed for surface degradation via scanning electron microscopy and the bulk erosion by measuring the weight difference. The surface roughness greatly increased in strained Pellethane with scanning electron microscopy (SEM) evidence of deep cracks and holes or ragged and stretched fractures perpendicular to the direction of stress. Carbothane showed a lower degradation compared with Pellethane under mechanical constraint.

Current Directions in Biomedical EngineeringVol. 10(4)
Institute for ImplantTechnology and Biomaterials (DE)
Openalex Percentile: Top 56%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.